System Errors
Code
Type
Description
Code
Code
Type
Type
Description
Description
QDA1
Differential
Pressure D
Over A
QDB1
Differential
Alarm
Pressure D
Over B
QDC1
Differential
Pressure D
Over C
QAD2
Differential
Pressure A
Over D
QBD2
Differential
Alarm
Pressure B
Over D
QCD2
Differential
Pressure C
Over D
106
Problem
Problem
Problem
Differential pressure
is low between driving
component and second
component. This alarm
is active only during Mix
mode.
Differential pressure is
high between driving
component and second
component. This alarm
is active only during Mix
mode.
Cause
Cause
Cause
There is a leak on the
second component side.
The second component
side pump is cavitating.
There is a leak on the
driving component side.
The driving component
side pump is cavitating.
Solution
Solution
Solution
Check the system for
internal and external
leaks on all manifolds
and plumbing for the
second component.
Check paint supply on
the second component
side, increase paint
supply pressure.
Check the system for
internal and external
leaks on all manifolds
and plumbing for the
driving component.
Check paint supply on
the driving component
side, increase paint
supply pressure.