Graco ProMix PD3K Plus Operation page 50

Proportioner for automatic spray applications
Table of Contents

Advertisement

Operation Using a Programmable Logic Controller (PLC)
Write Material
Material Ready
Ready Flag
Write
Write
Material
Ready
The Write Material Ready Flag command is used to signal to the PD3K+ that the upstream material management has
the appropriate component loaded at the inlet valve stack(s) of the pump(s) prior to a recipe change. This flag is
only used when multiple materials for a pump are fed to the PD3K+ via a single valve at the inlet valve stack (i.e. a
piggable system). See
NOTE: This flag should be cleared prior to or during a material change operation upstream of the inlet valve stack to
NOTE:
NOTE:
avoid having the wrong material being fed into the pump during a recipe change.
Example: Setting the Material Ready Flag for Pump 1.
Parameter Description
DCS
DCS
DCS Register
Register
Register
Parameter
Parameter
DCS
Write Material Ready Flag
Command
Argument 0
Material Ready Status
Argument 1
Pump Number
Acknowledge
Command Acknowledged
Return 0
Mix Fill Set Point
Return 1
Pump Number
Read User
User ID ID ID
Read
Read
User
The Read User ID command reads back the current User ID. See
Log and User ID. The User ID can be up to ten ASCII characters in length and is packaged as three little endian
segments of ASCII characters. No arguments are required.
Example: Read User ID that is currently "John Doe".
DCS Register
Register
Parameter
Parameter Description
Parameter
DCS
DCS
Register
Read User ID
DCS
Command
Acknowledge
Command Acknowledged
Return 0
User ID characters [3:0]
(ASCII)
Return 1
User ID characters [7:4]
(ASCII)
Return 2
User ID characters [9:8]
(ASCII)
50
Flag
Flag
Custom Valve Mapping, page 84
Description
Description
Description
Description
for more info on Single inlet valve stacks.
Data
Units
Value
Data
Data
Units
Units
Value
Value
Type
Type
Type
uint32
NONE
6
uint32
NONE
1
uint32
NONE
1
uint32
NONE
2 = ACK
uint32
NONE
1
uint32
NONE
1
Usage Screen, page
Data
Data
Data
Units
Units
Units
Value
Value
Value
Type
Type
Type
uint32
10
NONE
uint32
NONE
2 = ACK
uint32
NONE
0x6E686F4A = ['n',
'h', 'o', 'J']
uint32
NONE
0x656F4420 = ['e',
'o', 'D', ' ']
uint32
0x0 = [null]
NONE
Range
Range
Range
0 - 19
0 := Not
Ready/No OP
1 := Material
Ready
1 - 4
0 - 4
0 := Not
Ready/No OP
1 := Material
Ready
1 - 4
65, for more details on Job
Range
Range
Range
0 - 19
0 - 4
N/A
N/A
N/A
3A6287E

Advertisement

Table of Contents
loading

Table of Contents