Graco ProMix PD3K Plus Operation page 28

Proportioner for automatic spray applications
Table of Contents

Advertisement

Operation Using a Programmable Logic Controller (PLC)
OUTPUT
OUTPUT REGISTER
OUTPUT
REGISTER 01:
REGISTER
01: Event
01:
The Event Flag register indicates a system error has
occurred that requires user acknowledgment. Only
system errors of type Alarm or Deviation will require
user acknowledgment.
• The value is 0 if there are no new system errors
that require acknowledging.
• The value is 1 if there is at least one new system
error that requires user acknowledgment.
A system error may be acknowledged at
the system's ADM or remotely. See INPUT
REGISTER 01: Clear Active Alarm/Deviation in
ProMix PD3K+ Network Inputs, page
OUTPUT
OUTPUT
OUTPUT REGISTER
REGISTER 02:
REGISTER
02:
02: Actual
The Actual Mix Flow/Pressure register reports
the instantaneous mixing flow rate in cc/min or
mixing pressure in PSI. The value displayed
will correlate to the Fluid Control setting, see
System Screen 6, page
"Flow", this register will display flow rate, if set to
"Pressure", this register will display pressure.
NOTE: This register is valid only during a mix
NOTE:
NOTE:
operation.
OUTPUT
OUTPUT REGISTERS
OUTPUT
REGISTERS
REGISTERS 03,
Mix
Mix Ratio
Mix
Ratio Component
Ratio
Component
Component A, A, A, B, B, B, C, C, C, and
The Actual Mix Ratio Component register contains
the instantaneous calculated ratio value of that
particular component in the current recipe.
• The value reported is the ratio value multiplied by
1000, regardless of the selected ratio format.
Example
: Value = 4000 >> Component has a
proportional relationship of 4.000 as compared to the
other components.
Example (percent ratio formats)
Component is 30.000% proportion of total mixed
material.
• If a component is not included as part of a recipe,
(ratio value of 0) this value will be 0.
These registers are valid only during a mix operation.
OUTPUT
OUTPUT
OUTPUT REGISTER
REGISTER 07,
REGISTER
07, 08,
07,
Remaining
Remaining
Remaining Stage
Stage 1, 1, 1, 2, 2, 2, and
Stage
The Actual Mix Potlife Remaining registers reports
the current amount of time remaining in the potlife of
the mixed components in seconds, for each stage of
the fluid stream, individually.
NOTE:
NOTE:
NOTE: If the potlife time is disabled for any of the mix
stages of the fluid stream, or at initial power up of the
system, this value will be 0xFFFFFFFF.
28
Event
Event Flag
Flag
Flag
34.
Actual Mix
Actual
Mix
Mix Flow/Pressure
Flow/Pressure
Flow/Pressure
73. If Fluid Control is set to
03, 04,
03,
04, 05,
04,
05, and
05,
and 06:
and
06: Actual
06:
Actual
Actual
and
and D D D
: Value = 30000 >>
08,
08, 09:
09: Actual
09:
Actual
Actual Mix
Mix Potlife
Mix
Potlife
Potlife
and 3 3 3
and
OUTPUT REGISTER
OUTPUT
OUTPUT
REGISTER
REGISTER 10:
10: Gun
10:
The Gun Trigger Input Status register contains the
status of the Gun Trigger Discrete Inputs for guns
1, 2, and 3, as applicable. The register is formatted
as a bit vector with bits 0, 1, and 2 representing gun
trigger inputs 1, 2, and 3, respectively.
• A bit value of 0 indicates the input is OPEN (gun
not triggered).
• A bit value of 1 indicates the input is CLOSED (gun
triggered).
Example
A value of 3 (Bit 2 = 0, Bit 1 = 1, Bit 0 =
:
1) >> Gun 1 and 2 are triggered, but Gun 3 is not
triggered.
NOTE:
NOTE: If the system is not using multiple guns, this
NOTE:
value will only change between 0 and 1.
This data register is valid only for systems configured
to use discrete inputs for gun triggers. See Gun
Trigger Signal on
System Screen 6, page
OUTPUT REGISTER
REGISTER 11:
11: Active
OUTPUT
OUTPUT
REGISTER
11:
The Active Gun register indicates which gun is
currently in use or was last in use.
NOTE: This register will always be equal to 1 if not
NOTE:
NOTE:
using multiple guns
OUTPUT REGISTER
REGISTER 12:
12: Job
OUTPUT
OUTPUT
REGISTER
12:
The Job Number register will show the number of
the current job.
OUTPUT REGISTER
REGISTER 13:
13: Job
OUTPUT
OUTPUT
REGISTER
13:
The Job Total Sprayed Volume reports the total
volume of sprayed material during the current job in
cc. The total is the sum of components A, B, C, and
D.
OUTPUT
OUTPUT REGISTER
OUTPUT
REGISTER
REGISTER 14:
14: Job
14:
The Job Solvent Volume reports the total solvent
volume that has been dispensed during the current
job, in cc.
Gun Trigger
Gun
Trigger Input
Trigger
Input
Input Status
Status
Status
73.
Active Gun
Gun
Active
Gun
Job Number
Number
Job
Number
Job Total
Total Sprayed
Sprayed Volume
Volume
Job
Total
Sprayed
Volume
Job
Job Solvent
Solvent
Solvent Volume
Volume
Volume
3A6287E

Advertisement

Table of Contents
loading

Table of Contents