Graco ProMix PD3K Plus Operation page 37

Proportioner for automatic spray applications
Table of Contents

Advertisement

Network Input
Input Data
Data Map
Network
Network
Input
Data
Network
Network
Network
Modbus
Modbus
Modbus
Input
Input
Input ID ID ID
Register
Register
Register
0000
41100
0001
41102
0002
41104
0003
41106
0004
41108
0005
41110
0006
41112
0007
41114
0008
41116
0009
41118
3A6287E
Map (Write/Read)
(Write/Read)
Map
(Write/Read)
Parameter Name
Parameter
Parameter
Name
Name
System Mode Command
Clear Active Alarm/Deviation
Goto Recipe Number
Mix Control Set Point
Mix Fill Set Point
Pump Flush Sequence #/Prime
Material #
Flush/Prime Pump Command
Job Complete
Gun Trigger State
Set Active Gun
Operation Using a Programmable Logic Controller (PLC)
Data
Data
Data
Type
Type
Type
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
Units
Units
Units
Range
Range
Range
0 = No OP
1 = Power Pumps
2 = Remote Stop
3 = Recipe Change
4 = Mix Fill
5 = Mix
6 = Purge A
7 = Purge B
8 = Purge C
9 = Purge D
10 = Standby
11 = Recipe Purge
NONE
12 = Solvent Push
NONE
1 = Clear Active
Alarm/Deviation
0, 1 - 40
NONE
cc/min or
1 - 2000
PSI
cc/min or
1 - 2000
PSI
NONE
1 - 10, 1 - 54
0 = NO OP
1 = Flush Pump 1
2 = Prime Pump 1
3 = Flush Pump 2
4 = Prime Pump 2
5 = Flush Pump 3
6 = Prime Pump 3
7 = Flush Pump 4
8 = Prime Pump 4
9 = Fill Line
10 = Flush Line
NONE
11 = Stop Line Fill/Flush
1 := Trigger job complete
NONE
NONE
0 = Gun not triggered
1 = Gun triggered
NONE
1 - 3
37

Advertisement

Table of Contents
loading

Table of Contents