Graco ProMix PD3K Plus Operation page 70

Proportioner for automatic spray applications
Table of Contents

Advertisement

Setup Mode Screens
Mix Volume
Volume Percent
Percent
Mix
Mix
Volume
Percent
If needed, solvent may be pushed past the mix
manifold and into the mix hose, or manifolds and
hoses if multiple stages. To prevent atomizing
solvent, it may only be dispensed to a percent of the
total mix hose volume. The default value is 0%, which
will not dispense solvent beyond the mix manifold
that introduces the resin. The mix hose volume is
set by the Stage
Stage # # # Hose
Stage
Hose Length
Hose
Diameter fields. See
Diameter
Diameter
System Screen 5, page
The displayed volume shows the total amount of
solvent to be dispensed during the solvent push
sequence. This volume includes, at minimum, the
total fluid stream volume from the inlet color stack
to the mix manifold. Additionally, this volume will
include a percentage of the total mix hose volume,
if set to greater than 0%.
70
Length and Stage
Length
Stage # # # Hose
Stage
Hose
Hose
73.
If using an electrostatic gun, to reduce the risk
of fire and explosion, confirm the mix hose
parameters are accurately represented in the
settings.
The solvent push sequence is initiated
using a soft key on the Spray Screen (see
Spray Screen, page
62) or a PLC command (see
ProMix PD3K+ Network Inputs, page
Timing is critical to avoid having the solvent push
sequence end before the last part has been finished.
The system will go into Standby and must complete a
recipe change before it can mix again.
34).
3A6287E

Advertisement

Table of Contents
loading