Code for switching the „DURESS" output and relay 1
This code is generated by adding the value "2" to the first digit of user code 1.
Example:
If user code 1 is "1234" then the code is "3234".
In the programming example above, the programmed user code 1 is "8321" and so the
code "0321" must be used.
0 3 2 1
This code has the same function as user code 1 but also switches the "DURESS" output
(contact 16) to ground. This code allows the relay to be switched ON or OFF (depending
on the programming). The "DURESS" output can be switched on with this code, but
user code 1 must be used in order to switch back to an open contact. In this case, the
relay does not switch and only the "DURESS" output is switched back.
Using the short code
If you have programmed an output to allow the use of the short code (42#, 52#, 62#)
then you can switch the output using only the first two digits of the user code. The
short code can be used to switch all three relays, but take note of the programming
that you have done.
The respective full user code must be entered in order to switch the relay(s) off again.
In the programming example, output 3 was programmed to allow the use of the short
code. User code 3 is "9270" and so the short code is "92".
9 2
*
9 2 7 0
58
Relay 1 engages for 5 seconds and the "DU-
RESS" output switches to ground.
Output 3 switches on