Technical information

Using the PJLink function

The network function of this projector supports the PJLink class 1 and class 2, and the PJLink protocol can be
used to perform projector setting and projector status query operations from a computer.
Note
f Setting the password of the administrator account ( x page 123) is required for using the PJLink function of the projector.
PJLink commands
The following table lists the PJLink commands supported by the projector.
f x characters in tables are non-specific characters.
Class
Command
Control details
1
POWR
Power supply control
Power supply status
1
POWR?
query
INPT
Input selection
1, 2
INPT?
Input selection query
Shutter control/audio
AVMT
output control
1
Shutter status query/
AVMT?
audio output status
query
1
ERST?
Error status query
Light source status
1
LAMP?
query
1, 2
INST?
Input selection list query 11 12 21 32 33 36
1
NAME?
Projector name query
Manufacturer name
1
INF1?
query
1
INF2?
Model name query
166 - ENGLISH
Chapter 7  Appendix — Technical information
Parameter/
response string
0
1
0
1
11
12
21
32
33
36
10
11
20
21
30
31
11
21
30
31
xxxxxx
xxxxxx
xxxxx
Panasonic
PT-FRZ60
PT-FRZ50
Standby
Power on
Standby
Power on
COMPUTER1
COMPUTER2
VIDEO
HDMI1
DIGITAL LINK
HDMI2
Shutter function disabled (shutter: open), mute function disabled
Shutter function enabled (shutter: closed), mute function disabled
Shutter function disabled (shutter: open), mute function disabled
Shutter function disabled (shutter: open), mute function enabled (muted)
Shutter function disabled (shutter: open), mute function disabled
Shutter function enabled (shutter: closed), mute function enabled
(muted)
Shutter function enabled (shutter: closed), mute function disabled
Shutter function disabled (shutter: open), mute function enabled (muted)
Shutter function disabled (shutter: open), mute function disabled
Shutter function enabled (shutter: closed), mute function enabled
(muted)
Indicates fan errors, and returns 0
1st byte
or 2.
Indicates light source errors, and
2nd byte
returns 0 or 2.
Indicates temperature errors, and
3rd byte
returns 0 - 2.
4th byte
Returns 0.
5th byte
Returns 0.
Indicates other errors, and returns 0
6th byte
- 2.
1st number (1 - 5 digits): Light source runtime
2nd number: 0 = Light source off, 1 = Light source on
Returns the name set in the [NETWORK] menu → [PROJECTOR
NAME].
Returns manufacturer name.
Returns model name.
Remark
f 0 = No error is
detected
f 1 = Warning
f 2 = Error

Advertisement

Table of Contents
loading

Table of Contents