Installing the Switch 2650
Sample Network Topologies

As a Segment Switch

Server with
"Gigabit"
Ethernet NIC
Switch 2650
"Fast"
Ethernet
Hubs
Twisted-pair
"straight-through"
cables to
end nodes
The Switch 2650 also works well as a segment switch. That is, with its high
performance, it can be used for interconnecting network segments—simply
connect the network hubs that form those segments to the switch, or you can
also connect other switches.
In the illustration above, two "Fast" Ethernet hubs with PCs, printers, and local
servers attached, are both connected to a Switch 2650. The devices attached
to the two hubs can now communicate with each other through the switch.
They can also all communicate with the server that is connected to a
1000Base-T port on the switch.
Because the Switch 2650 has the "HP Auto-MDIX" and "IEEE Auto MDI/
MDI-X" features, the connections between the switch and the hubs, and
between the switch and end nodes or servers can be through category 5
"straight-through" or "crossover" twisted-pair cable. Category 3 or 4 cable can
also be used if the connection is 10 Mbps only. In all cases, the device ports
must be configured to auto negotiate the link characteristics for this feature
to work.
The switch, in turn, can be connected to a network backbone through fiber-
optic cabling connected to a Gigabit-SX, -LX, or -LH mini-GBIC installed in the
switch. Now, all the devices on these network segments can access other
network resources that are connected elsewhere on the network backbone.
2-20
"crossover" cable for 1000 Mbps connection to server
Gig-T
Ports
48
46
47
47
45
M
43
44
T
50
41
42
49
M
Mini-
40
T
Ports
GBIC
38
39
36
37
Gigabit
port
34
35
M) for
each
33
only
one
(T or
32
31
33
48
!
Use
30
31
28
29
26
27
24
25
22
23
21
19
20
17
18
16
32
34
14
15
15
17
12
13
11
9
10
(1 - 48)
7
8
Base-TX
Ports
5
6
10/100
4
2
3
1
16
18
hp procu
rve
1
h
2650
switc
A
J4899
Mbps
Self
Lnk
on =
1000
Test
Port
Act
= 100
Mbps,
View
LED
FDx
flash
Fan
Spd
off =
10 Mbps,
Powe
r
Status
mode:
Clear
Spd
Fault
Reset
Printers
Category 5E twisted-pair "straight-through" or
Gigabit
Twisted-pair "straight-
fiber-optic cable
through" or "crossover"
to backbone
Printers
cables to hubs
PCs,
printers,
and local
servers