Owon HDS272S User Manual page 28

Handheld oscilloscope
Hide thumbs Also See for HDS272S:
Table of Contents

Advertisement

Cont
Cap
2.Range indication: Manual means manual range; Auto means automatic
range.
3. Current measurement range.
4. Indicating that there is a USB cable inserted.
5. Battery power indication.
6. "Hold" can keep the current reading on the display.
7. Measurement value and unit.
8. Display of switching resistance, buzzer, diode and capacitance
measurement function.
9. The selected range V or mV in voltage measurement; the selected current
range A or mA in current measurement.
10. To choose AC or DC voltage measurement.
11. To choose to AC or DC current measurement.
12. Display of relative value measurement function (only available when
measuring DC current, DC voltage and resistance).
------
On/Off measurement
------
Capacitance measurement
25