3.5
Power ON/OFF Sequence
To prevent a latch-up or DC operation of LCD assembly, the power on/off sequence
should be as the diagram below.
Power Sequence Timing
Parameter
T1
T2
T3
T4
T5
T6
T7
T8
T9
IDK-1110P User Manual
Value
Min.
Typ.
0.5
-
0
-
0
-
500
-
200
-
20
-
5
-
10
-
10
-
14
Unit
Max.
10
[ms]
50
[ms]
50
[ms]
-
[ms]
-
[ms]
-
[ms]
300
[ms]
-
[ms]
-
[ms]