PROGRAMMING LOCATIONS

L
LOCATION 0 - PHONE NUMBER 1 (20 segments, numerical data)
The first telephone number is programmed in location 0. A "14" indicates the end of the phone number. Delays of four
seconds can be programmed at any point in the phone number by programming a "13" in the appropriate segment. If
tone dialing is desired, program a "15" in the segment where tone dialing should begin. If the entire number should be
tone dialing, program a "15" in the first segment. Program an A11" for a Ar@, and a A12" for a A#@.
L
LOCATION 1 - ACCOUNT CODE FOR THE PHONE #1 (6 segments, numerical data)
The account code sent when Phone #1 is dialed is programmed in location 1. Program a A10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments.
L
LOCATION 2 - COMMUNICATOR FORMAT FOR PHONE #1 (1 segment, numerical data)
Location 2 contains the communicator format used to transmit to the receiver connected to Phone #1. Consult the
instructions for your central station receiver to determine which format is compatible. Select a format from Table X-1
COMMUNICATOR FORMAT SELECTIONS. If you require a format other than those listed, review the override
options described in location 18, to build the appropriate format. A "15" must be programmed in location 2 in addition
to the entries in location 18 in order to create a special format. If this location contains a "0", the built-in communicator
will be disabled, and the NX-8E will function as a local only control.
Table X-1 COMMUNICATOR FORMAT SELECTIONS
DATA
0
Local
1
Universal 4+2
2
3+1 fast (or 4+1)
3
Reserved
4
Pager
5
3/1 or 4/1 slow
6
3/1 or 4/1 slow
7
3/1 or 4/1 fast
8
3/1 or 4/1 fast
9
3/1 or 4/1 fast with parity
10
3/1 or 4/1 fast with parity
11
4+2 express
12
4+2 fast
13
Ademco Contact ID
14
SIA
15
Custom format
L
LOCATION 3 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE # 1 (2 segments, numerical data)
Segment 1- Dial attempts: Location 3, Segment 1 is used to enter the number of dial attempts (1 to 15 Attempts) the
communicator will make to Phone #1 before ending the notification process. Factory default is "8" and the
communicator will make eight (8) attempts to the first number.
Segment 2- Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8E to
make the designated number of attempts to Phone #2 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8E to stop trying to communicate after the designated
NX-8E CONTROL
FORMAT
Communicator is disabled
Two digit event code 1800hz transmit 2300hz handshake double round parity
40pps
One digit event code 1900Hz transmit 1400Hz handshake double round parity
20pps
Reserved
2 digit event code DTMF transmission
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex
capability
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex
capability
2 digit event code DTMF transmission
Two-digit event code 1900hz transmit 1400hz handshake double round parity
20 p.p.s.
DTMF (see pages 69 & 70)
FSK (see pages 69 & 70)
(See location 18, page 17)