GE NETWORX Series Installation And Start-Up Manual page 22

Hide thumbs Also See for NETWORX Series:
Table of Contents

Advertisement

DATA
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is
armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will
15
bypass when the "Group Bypass" command is entered at the keypad. This zone will automatically bypass if
enabled in Segment 1 of Location 23.
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped and
16
the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at the keypad.
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip during exit
17
delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to
enable tamper on a wireless transmitter.
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when
the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times.
18
This zone will automatically bypass if enabled in Segment 1 of Location 23. This zone type can be used to
enable tamper on a wireless transmitter.
INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the
19
Armed LED is on. This zone type can be used to enable tamper on a wireless transmitter.
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. The lack of a trip during exit
20
delay will enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to
enable tamper on a wireless transmitter.
GAS DETECTION- Creates an instant alarm regardless of the armed state of the control panel. It will display
21
on the keypad and activate the keypad sounder.
LOW TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control panel. It
22
will display on the keypad and activate the keypad sounder.
HIGH TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control panel. It
23
will display on the keypad and activate the keypad sounder.
MANUAL FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is
24
shorted. It will also rapidly flash the Fire LED indicating a trouble if the zone is open.
CHIME ONLY - Creates no alarm regardless of the armed state of the control panel. It will chime anytime it is
25
faulted and will display on the keypad. Local only.
INTERIOR FOLLOWER DELAY 2 - This zone will be instant when the system is armed and no entry or exit
26
delay is being timed. It is delayed during entry and exit delay 2 times. This zone will automatically bypass if
enabled in Segment 1 of Location 23.
INTERIOR FOLLOWER FORCE ARMABLE - This zone will be instant when the system is armed and no
27
entry or exit delay is being timed. It is delayed during entry and exit delay 1 times. This zone will automatically
bypass if enabled in Segment 1 of Location 23.
ENTRY/EXIT FORCE ARMABLE DELAY 2 - A trip will start entry delay 2. The lack of a trip during exit delay
28
will enable the Automatic Bypass or Instant mode if so programmed.
INTERIOR FOLLOWER WITH ACTIVITY SUPERVISION ENABLED - This zone will be instant when the
system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. It will
29
send a report if the zone activity time is reached without a change of state. Refer to Location 40 / Segment 11.
This zone will automatically bypass if enabled in Segment 1 of Location 23.
ENTRY/EXIT WITH ACTIVITY SUPERVISION ENABLED- A trip will start entry delay 1. It will send a report if
30
the zone activity time is reached without a change of state. Refer to Location 40 / Segment 11. The lack of a
trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
L
LOCATION 25 - ZONES 1-8 ZONE TYPE (8 segments, numerical data)
Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 26 - PARTITION SELECT, ZONES 1-8 (8 segments, feature selection data)
Location 26 is used to select the partition(s) that zones 1 - 8 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions
are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number.
Location 26 has 8 segments. Segment 1 corresponds to zone 1, and Segment 8 corresponds to zone 8.
Segments 1 - 8:
1 = Partition #1
2 = Partition #2
20
DESCRIPTION OF DEFAULT ZONE TYPES
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
NX-8E CONTROL