PARTITION 8, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
Segment #5 & #6 RESERVED
110
33
ZONE TYPE 1 ALARM EVENT CODE
111
33
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
1
Fire (enable for fire zone).
2
24 Hour (enable for non-fire 24 hour
zone).
3
Keyswitch zone.
4
Follower (enable for burg zones that are
instant during non-entry times).
Segment #2 (Circle numbers to program)
1
Keypad audible on alarm.
2
Yelping siren on alarm.
3
Temporal siren on alarm.
4
Chime.
Segment #3 (Circle numbers to program)
1
Fast Loop Response.
2
Double End of Line Tamper zone.
3
Trouble zone (Day zone).
4
Cross Zone.
Segment #4 (Circle numbers to program)
1
Zone Activity Monitor.
2
End of Line Resistor Defeat.
3
Delays alarm activation 60 seconds.
4
Zone acts as request to exit input.
Segment #5 - Reserved
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF
EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND
THESE DEFAULTS.
LOC
PG
112
33
ZONE TYPE 2 ALARM EVENT CODE
113
33
ZONE TYPE 2 CHARACTERISTIC SELECT
114
33
ZONE TYPE 3 ALARM EVENT CODE
115
33
ZONE TYPE 3 CHARACTERISTIC SELECT
116
34
ZONE TYPE 4 ALARM EVENT CODE
117
34
ZONE TYPE 4 CHARACTERISTIC SELECT
118
34
ZONE TYPE 5 ALARM EVENT CODE
119
34
ZONE TYPE 5 CHARACTERISTIC SELECT
120
34
ZONE TYPE 6 ALARM EVENT CODE
121
34
ZONE TYPE 6 CHARACTERISTIC SELECT
122
34
ZONE TYPE 7 ALARM EVENT CODE
123
34
ZONE TYPE 7 CHARACTERISTIC SELECT
124
34
ZONE TYPE 8 ALARM EVENT CODE
125
34
ZONE TYPE 8 CHARACTERISTIC SELECT
126
34
ZONE TYPE 9 ALARM EVENT CODE
127
34
ZONE TYPE 9 CHARACTERISTIC SELECT
128
34
ZONE TYPE 10 ALARM EVENT CODE
129
34
ZONE TYPE 10 CHARACTERISTIC SELECT
58
DESCRIPTION
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
DESCRIPTION
DEFAULT
0
0
0
0
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit
times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).
Bypassable.
Group Shunt.
Force armable.
Entry Guard.
Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.
Reserved.
Reserved.
Reserved.
Reserved.
DEFAULT
2
2-125-78-0-0
7
5-1245-5678-0-0
5
45-125-5678-0-0
5
457-125-5678-0-0
4
0-1245-5678-0-0
0
2-0-78-0-0
1
1-13-378-0-0
7
6-1245-5678-0-0
2
24-5-78-0-0
DATA
_
_
_
_
_
DATA
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
NX-8E CONTROL