GE NETWORX Series Installation And Start-Up Manual page 27

Hide thumbs Also See for NETWORX Series:
Table of Contents

Advertisement

LOCATION 47 - AUXILIARY OUTPUT #1, EVENT AND TIME (2 segments, numerical data)
Segment 1:
Use the chart on page 25 to select the event that will activate Auxiliary Output 1.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 1, Location 46). Programming a "0" makes the output follow the event.
LOCATION 48 - AUXILIARY OUTPUT #2, EVENT AND TIME (2 segments, numerical data)
Segment 1:
Use the chart on page 25 to select the event that will activate Auxiliary Output 2.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 2, Location 46). Programming a "0" makes the output follow the event.
LOCATION 49- AUXILIARY OUTPUT #3, EVENT AND TIME (2 segments, numerical data)
Segment 1:
Use the chart on page 25 to select the event that will activate Auxiliary Output 3.
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 3, Location 46). Programming a "0" makes the output follow the event.
LOCATION 50- AUXILIARY OUTPUT #4, EVENT AND TIME (2 segments, numerical data)
Segment 1:
Use the chart on page 25 to select the event that will activate Auxiliary Output 4. .
Segment 2:
Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 4, Location 46). Programming a "0" makes the output follow the event.
Table XI-1 AUXILIARY OUTPUT EVENT SELECTION
DATA
EVENT
/ Burglary Alarm
0
/ Fire Alarm
1
/ 24 Hour Alarm
2
/ Trouble Alarm
3
/ Tamper Alarm
4
5
Yelping Siren (Burglary)
6
Temporal Siren (Fire)
7
Any Siren
8
Any Bypass
9
AC Fail
10
Low Battery
/ Duress
11
/ Aux 1 Keypad Zone
12
/ Aux 2 Keypad Zone
13
/ Panic Keypad Zone
14
15
Keypad Tamper
/ Autotest
16
17
Alarm Memory
˜ Events 49 & 50 require NX-408, NX-416, or NX-448 wireless receivers to operate.
/ If set to follow condition, these events will be 1 second.
Notes: When Event 48 is programmed, it is possible to program a user code's authorization to select which output(s)
a particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 4 correspond to that code
activating outputs 1 - 4 respectively. (See programming the LED keypads on page 8.)
NX-8E CONTROL
DATA
EVENT
18
Entry
19
Exit
20
Entry or Exit
21
Armed State
22
Disarmed State
23
Ready
24
Not Ready
25
Fire
26
Fire Trouble
27
Chime
/ Expander Trouble
28
29
Dynamic Battery Test Time
30
Open Period
31
Closed Period
32
Listen-In
33
Line Seizure
34
Ground Start
35
Fail To Communicate
DATA
EVENT
36
Telephone Line Fault
37
Program Mode
38
Download In Process
39
Ground Fault
40
Short Circuit (Over-current)
41
Box Tamper
42
Siren Tamper
43
Any Open
44
Any Short
Any Fault (Open/ Short on
45
Non-Fire Zone)
/
46
Any Alarm
47
Beeping Keypad
/
48
Code Entry (See note below)
˜
49
Key FOB Function 1
/
˜
50
Key FOB Function 2
/
69
Forced Door Alarm
70
Forced Door Restore
25

Advertisement