LOCATION 173 - PARTITION SELECT, ZONES 57-64 (8 segments of feature selection data)
Location 173 is used to select the partition(s) that zones 57-64 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 57 and Segment 8 corresponds to zone 64.
Segments 1 - 8:
1 = Partition #1
2 = Partition #2
L
LOCATION 174 - ZONES 65-72 ZONE TYPE (8 segments, numerical data)
Location 174 contains the Zone Type for zones 65 - 72. Segment 1 is for zone 65; Segment 8 is for zone 72. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 175 - PARTITION SELECT, ZONES 65-72 (8 segments of feature selection data)
Location 175 is used to select the partition(s) that zones 65-72 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 65 and Segment 8 corresponds to zone 72.
Segments 1 - 8:
1 = Partition #1
2 = Partition #2
L
LOCATION 176 - ZONES 73-80 ZONE TYPE (8 segments, numerical data)
Location 176 contains the Zone Type for zones 73-80. Segment 1 is for zone 73; Segment 8 is for zone 80. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 177 - PARTITION SELECT, ZONES 73-80 (8 segments of feature selection data)
Location 177 is used to select the partition(s) that zones 73-80 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 73 and Segment 8 corresponds to zone 80.
Segments 1 - 8:
1 = Partition #1
2 = Partition #2
L
LOCATION 178 - ZONES 81-88 ZONE TYPE (8 segments, numerical data)
Location 178 contains the Zone Type for zones 81-88. Segment 1 is for zone 81; Segment 8 is for zone 88. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 179 - PARTITION SELECT, ZONES 81-88 (8 segments of feature selection data)
Location 173 is used to select the partition(s) that zones 81 - 88 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 81 and Segment 8 corresponds to zone 88.
Segments 1 - 8:
1 = Partition #1
2 = Partition #2
L
LOCATION 180 - ZONES 89-96 ZONE TYPE (8 segments, numerical data)
Location 180 contains the Zone Type for zones 89 - 96. Segment 1 is for zone 89; Segment 8 is for zone 96. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
38
3 = Partition #3
4 = Partition #4
3 = Partition #3
4 = Partition #4
3 = Partition #3
4 = Partition #4
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
5 = Partition #5
6 = Partition #6
5 = Partition #5
6 = Partition #6
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
7 = Partition #7
8 = Partition #8
7 = Partition #7
8 = Partition #8
7 = Partition #7
8 = Partition #8