6.4.2.15. COMMUNICATION

Set the RS485 communication protocols within this submenu to match the
protocols from the DVR.
• PROTOCOL — Scroll left or right to select a communication protocol - PELCO-D
or PELCO-P. Wirepath devices use Pelco-D.
• ADDRESS — Scroll left or right to select a unique ID number from 0 to 225 to
identify the camera on the RS485 loop.
Note— Each device in the RS485 connection MUST be set to a unique address
number for proper RS-485 communication.
• BAUDRATE — Scroll left or right to choose a baud rate for RS485 communication
between the camera and controller. Baud rate options include 4800, 9600,
19200, 38400, and 57600.
Note— ALL devices in the RS485 connection must be set to the same baud rate
for proper RS-485 communication.
• DATABIT — 8
• PARITY — OFF
• STOPBIT — 1

6.4.2.16. LANGUAGE

Select one of 7 language options—English, Spanish, Russian, German,
Portuguese, French, and Japanese.

6.4.2.17. VERSION

To view the version of firmware currently running on the camera, select VERSION.
© 2014 Wirepath Surveillance
COMMUNICATION
PROTOCOL
ADDRESS
BAUDRATE
DATABIT
PARITY
STOPBIT
RETURN
WPS-765-DOM-AH Installation Manual
PELCO-D
050
4800
8BIT
OFF
1BIT
25