YASKAWA GPD315/V7-4X Technical Manual page 127

Table of Contents

Advertisement

Table A1-1. Drive Parameters - Continued
PARA-
METER
NAME
n096
Overtorque Detection (OL3)
Overtorque Detection
n097
Selection
note 5
Overtorque Detection
n098
Level (OL3)
Overtorque Detection
n099
Delay Time (OL3)
Up/Down Hold
n100
Memory
Speed Search
n101
Deceleration Time
Speed Search Operation
n102
Level
Torque Compensation Gain
n103
note 4
Torque Compensation
n104
Time Constant
Torque Compensation
n105
Iron Loss
n106
Motor Rated Slip note 4
Motor Line-to-line
n107
Resistance
Motor Leakage
n108
Inductance note 5
Torque Compensation
n109
Limit note 5
n110
Motor No-load Current
n111
Slip Compensation Gain note 4 0.0 to 2.5
Slip Compensation Primary
n112
Delay Time
Slip Compensation Selection
n113
During Regeneration note 5
Stall Prevention Above Base
n115
Speed During Run
Stall Prevention During Run,
n116
Accel/Decel Time Select
n117
Undertorque Detection
Select
Undertorque Detection
n118
Level
Undertorque Detection
n119
Time
n120
Frequency Reference 9 note 4
n121
Frequency Reference 10 note 4
n122
Frequency Reference 11 note 4
n123
Frequency Reference 12 note 4 0.00 to 400.00
n124
Frequency Reference 13 note 4
n125
Frequency Reference 14 note 4
n126
Frequency Reference 15 note 4
n127
Frequency Reference 16 note 4
SETTING RANGE
(AND UNITS)
0: Detection Disabled
1: Detect only at set frequency;
operation continues
2: Detect only at set frequency;
coast to stop
3: Detect during all frequency conditions;
operation continues
4: Detect during all frequency conditions;
coast to stop
0: Detected by output torque
1: Detected by output current
30 to 200
0.1 to 10.0
0: Disabled
1: Enabled
0.0 to 10.0
0 to 200%
0.0 to 2.5
0.0 to 25.5
0.0 to 6550
0.0 to 20.0
0.000 to 65.50
0.00 to 655.0
0 to 250
0 to 99
0.0 to 25.5
0: Disabled
1: Enabled
0: Disabled
(level is based on setting of n094)
1: Enabled
(level at Fmax is n094 x 0.4)
0: Follows acc/dec #1 (n019, n020)
or acc/dec #2 (n021, n022)
Note: Multi-Function input selectable
1: Follows acc/dec #2 (n021, n022)
always
0: Undertorque detection disabled
1: Detected during constant speed running.
Operation continues after detection
2: Detected during constant speed running.
Operation stops during detection
3: Detected during all frequency conditions.
Operation continues
4: Detected during all frequency conditions.
coast to stop
0 to 200%
Inverter rated current = 100%; if n097 = 0
(detection by torque); motor rated torque
becomes 100%
0.1 to 10.0
A1-5
SETTING
FACTORY
USER
INCREMENT
SETTING
SETTING
1
0
1
0
1 (%)
160
0.1 (sec)
0.1
1
0
0.1 (sec)
2
1 (%)
150
0.1
1.0
0.1 (sec)
Note 2
0.1 (W) or
Note 1
1 (W)
0.1 (Hz)
Note 1
0.001 (ohm)
Note 1
0.01 (mH)
Note 1
or 0.1 (mH)
1 (%)
150
1 (%)
Note 1
0.1
Note 2
0.1 (sec)
Note 2
1
0
1
0
1
0
1
0
1(%)
0
0.1 (sec)
0.1
0.00
0.01 (Hz)
0.00
(< 100 Hz)
0.00
or
0.00
0.1 (Hz)
0.00
(>= 100 Hz)
0.00
0.00
0.00
PARA.
REF.
5.20
5.10
5.18
5.18
5.26
2.2, 5.22
5.26
2.2
5.22
5.23
5.34
5.11