5.29 COPY FUNCTION
A.
Read Function (rEd)
The Read function reads the available parameter data from the drive and stores them in a EEPROM
in the digital operator. When the Read function is executed the previously stored parameter data is
cleared and replaced with newly read parameters.
DESCRIPTION
Set the highest parameter
access level.
This will allow all parameters
to be viewed and set.
Set Parameter Copy
Access Selection (n177) = 1
Execute upload (Read)
Using Parameter Read
Function Selection (n176)
Table 5-5. Reading Drive Parameters
KEY SEQUENCE
DSPL
Press the
key until the
is lit on the digital operator.
DATA
ENTER
Press
.
V
Press
three times.
DATA
ENTER
Press
.
V
Press and hold
until n177 is
displayed on the digital operator.
DATA
ENTER
Then press
.
V
Use the
key to set a "1" in the
display.
DATA
ENTER
Then press
.
V
Press the
key once.
DATA
ENTER
Then press
.
V
Press the
key once.
DATA
ENTER
Press
. "rED" will blink on the display
while reading.
5-47