Particularly in EMC critical environments, it is important to earth the shield at the terminal
block side (q.v. figure 5.3 – pin with black shrink tubing and blue ferule).
In case the ExCam IPQ6055 is supplied via a PoE capable device, an additional safe-
guarding of the power supply is not necessary. The power supply is executed by the PoE
network device via an electronic with intelligent set-up. The camera as well as the con-
nection is permanently monitored in order to avoid any failure or defects in case of a
short-circuit fault.
For a camera with terminal block execution, it is possible to operate the camera either
with a PoE capable network device or with a separate 48 V DC power supply (supply
voltage and network streams are self-sustaining) . In this event a n adequate supply safe-
guarding has to be dimensioned.
Recommended is a 300 mA medium time lag fuse.
5
4
8
7
9 (shield/
GND)
9
Figure 5.6 – RJ45 Contact assignment
1
2
6
3
10 (shield)
Figure 5.7 – SKDxx Pin assignment
Doc.-ID: 180409-PT08BA-SS-ExCam IPQ6055_en_rev.01.docx, page 15 of 24