ICP DAS USA I-7530A-MR-G User Manual page 74

Rtu to can
Table of Contents

Advertisement

0x000B
0x000C
Note3: This value is Data bit of RS-232/RS-422/RS-485.
Data bit
0x0000
0x0001
0x0002
0x0003
Note4: This value is Stop bit of RS-232/RS-422/RS-485.
Stop bit
0x0000
0x0001
Note5: This value is Parity of RS-232/RS-422/RS-485.
Parity
0x0000
0x0001
0x0002
Response command:
Field Name
Node ID
Function Code
Start Address
Word Count
I-7530A-MR Modbus RTU to CAN Converter User's Manual (Version 1.08, 07/2019) ------------- 74
115200 bps baud rate of RS-232/RS-422/RS-485.
230400 bps baud rate of RS-232/RS-422/RS-485.
Hexadecimal rule
5 bits Data formation
6 bits Data formation
7 bits Data formation
8 bits Data formation
Hexadecimal rule
1 Stop bit
2 Stop bits
Hexadecimal rule
None
Odd
Even
Size
Value Range
Hexadecimal rule
1 byte
0x01~0xF7
1 byte
0x10
2 bytes
0x0100
2 bytes
0x0005
Description
Description
Description
Response Example
0x01
0x10
0x0100
0x0002

Advertisement