3.4.2

Pair Connection Mode

The testing Utility screenshot is shown below.
Figure 3-29: The active area of the Utility in the Pair connection mode.
User can key-in any information to the edit box and select the end of
character. Then click the "Send" button to transmit the information to the
CAN network. When checking the "Timer (ms)", the Utility will transmit the
message periodically.
If the "Receive" is checked, the message sent from the I-7530A-MR
will automatically be received and displayed in the "Receive" text box.
Besides, users can click the "Clear" button to remove the messages on
the text box. In addition, users can click the "Save" button to save the
messages in the "Receive" text box into the "I-7530A-
MR_P_yyyyMMddmmss.txt " file. The indication of the file name is
described below.
I-7530A-MR Modbus RTU to CAN Converter User's Manual (Version 1.08, 07/2019) ------------- 41