Application 2:
This application architecture is the same as the one of application1. The
application architecture is show below. The difference will be discussed in the
following paragraph.
Configurations:
To apply this application, user need to configure the I-7530A-MR#1 and I-
7530A-MR#2 as follows. The RS-232 configurations of the I-7530A-MR#1 and
I-7530A-MR#2 are decided by the Device1 and Device2 RS-232 parameters.
I-7530A-MR#1 Configuration
Communication Descriptions:
The communication of this condition is similar with the communication of
condition 1. The difference is that the I-7530A-MR#2 of the application 1 will
transfer the RS-232 commands to Device2 immediately if it receives any CAN
message from the I-7530A-MR#1. The I-7530A-MR#2 of application 2 will not
transfer the RS-232 commands to Device2 until it has checked the end
character of RS-232 command (The end of RS-232 command is 'CR'). For
example, if the Device1 sends RS-232 commands "123456789", the Device2 in
application 1 will receive the data "12345678" immediately, and receive the data
"9" with a little delay. But, Device2 in application 2 will receive the data
"123456789" at the same time (Max. 256 bytes data at the same time).
I-7530A-MR Modbus RTU to CAN Converter User's Manual (Version 1.08, 07/2019) ------------- 58
Figure 5-2: The diagram of Application 2.
I-7530A-MR#2 Configuration