Retrieving The Error Memory - OEG 650 001 330 Installation And Operating Instruction

Multifunctional, capacity-controlled air/water heat pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 46
Parameter table for system setting
No.
Description
P98
The control signal of G1 valve
is inverted
P99
The control signal of G2 valve
is inverted
P100
The control signal of G3 valve
is inverted
Code
Error
E01
Sensor error outdoor air temperature
E02
Sensor error coil temperature
E03
Sensor error suction temperature
E04
Sensor error EVI inlet temperature
E05
Sensor error EVI outlet temperature
E06
Sensor error discharge temperature
E07
Sensor error DHW temperature
E08
Sensor error flow temperature
E09
Sensor error return temperature
E10
Sensor error refrigerant temperature
E11
Sensor error high pressure
E12
Sensor error low pressure
E13
High-pressure protection
E14
Low-pressure protection
E15
Water flow failure
E16
Communication failure
E17
Discharge temperature too high
E18-
Reserved
19
E20
IPM protection
E21
Reserved
E22
Water temperature differential too high
E23
DHW defrost 2x
E24
AC defrost 2x
Multi-functional DC inverter air/water heat pump
Standard
Range
650 001 330
0 = normal / 1 = inverted
0
0 = normal / 1 = inverted
0
0 = normal / 1 = inverted
0
Cause
Outdoor air temperature sensor, open circuit or short
circuit
Coil temperature, open circuit or short circuit
Suction temperature, open circuit or short circuit
EVI inlet temperature sensor, open circuit or short
circuit
EVI outlet temperature sensor, open circuit or short
circuit
Discharge temperature sensor, open circuit or short
circuit
DHW temperature sensor, open circuit or short
circuit
Flow temperature sensor, open circuit or short circuit
Return temperature sensor, open circuit or short
circuit
Sensor, open circuit or short circuit
• Sensor defective
• Open circuit or short circuit
• PCB defective
• Sensor defective
• Open circuit or short circuit
• PCB defective
• Excessive refrigerant
• Error throttling part
• Error pressure sensor
• Insufficient refrigerant
• Error throttling part
• Error pressure sensor
• Insufficient water
• Failure of flow switch
Communication failure main PCB and controller
• Insufficient refrigerant
• Failure throttling part
See detailed code in Annex C
Inspect circulation pump and filter
Defrost function in DHW mode has been activated
2x within 60 min.
Defrost function in A/C mode has been activated 2x
within 60 min.
Standard
Standard
Standard
6KW
9KW
12KW
18KW
650 001 331
650 001 332
650 001 333
0
0
0
0
0
0
0
0
0
73
Parameter modification
Retrieving error memory