50
3.1.4
Recommended
installation distances
3.1.5

Control unit

3.2
Installation examples
M
GB
OEG heat pumps are equipped with high-quality components to avoid and reduce sound
emissions. However, operating noise cannot be entirely avoided. Depending on the
installation location and pump model, the following minimum clearances towards sensitive
areas (e.g. bedroom windows) are recommended for the operation during the night.
based on DIN 4109-1, 32nd BlmSchV and TA noise
Distance in meters, operating mode: night mode
Terrain type/
Limit value
Installation position
Industrial areas
Business parks
Core areas, village areas,
mixed areas
General residential areas,
small housing estates
All-residential areas
Spa areas, hospitals,
nursing homes
The heat pump is equipped with a wired electronic control unit.
The control unit is installed inside the house. In order to avoid interferences, the connection
cable of the control unit should not be laid close to the main connection line.
You can request a variety of information from the control unit. Furthermore, users and
technicians are provided with all setting options required.
The control unit is used during installation and maintenance.
Under normal circumstances, the control unit does not need to be accessible for residents.
For the fi ve diff erent operating modes (see chapter 2 "System description"),
there is a variety of hydraulic integration options.
For the space-cooling modes, all water-carrying components must be insulated
impermeably and protected against corrosion.
The following application examples are only schematic diagrams. They must be
complemented by missing safety modules etc.
The safety-related equipment for DHW heating systems must be installed according to
DIN EN 12828.
In all systems the minimum volume fl ow in the heating circuit of the heat pump must be
adhered to. Non-observance can lead to failure.
Symbols and their meanings:
Heating circuit
Mixing valve for
M
set
heating / change-
over valve
M
T
Thermometer
Safety valve
M
Diaphragm expan-
Overfl ow valve
sion vessel
Multi-functional DC inverter air/water heat pump
Minimum distance to heat pump
650001330
650001331
dB(A)
6 kW
9 kW
70
1
1
50
1
1
45
2
2
40
3
4
35
5
7
35
5
7
M
W
F
K
M
Circulation
pump
Pressure gauge
Filter/dirt
M
separator (with
magnet)
T *
W
650001332
650001333
12 kW
18 kW
1
1
1
2
2
3
4
5
7
9
7
9
T *
U
Vent valve
Underfl oor
M
heating /
radiator
Temperature
sensor
M
+
Fresh-water
Draining
FZ
circulation set