Parameter modification
GB
Parameter table for system setting
No
Description
P00
ON/OFF
P01
Working mode
P02
Target temperature Heating
P03
Target temperature Cooling
P04
DHW target temperature
P05
Target temperature space
P06
A/C temperature difference
P07
DHW temperature difference
P08
A/C heating AU curve
max. temperature
(weather-compensated AU curve)
P09
A/C heating AU curve
parallel shifting value
(weather-compensated AU curve)
P10
Thermal disinfection cycle (days)
P11
Thermal disinfection start time
P12
Thermal disinfection runtime
P13
Thermal disinfection temperature
P14
Thermal disinfection mode
selection
P15
Night mode starting point
P16
Night mode ending point
P17
Night mode OFF/ON
P18
DHW AU OFF/ON
P19
A/C AU OFF/ON
P20
Working mode circulation pump
P21
Frost protection interval
circulation pump
P22
Ambient temp. to activate A/C
electrical heater
P23
Ambient temp. to activate DHW
electrical heater
P24
Electrical heater to activate the
temperature parallel shifting
value
P25
A/C frost protection temperature
P26
Multi-control defrost interval
P27
First defrost interval
P28
Defrost cycle
P29
Coil temperature to activate
defrost
P30
Coil temperature to deactivate
defrost
P31
Max. defrost time
P32
EEV control mode
P33
EEV manual setting of opening
steps (Heating)
P34
EEV manual setting of opening
steps (Cooling)
P35
In DHW mode, highest water
temperature for running
compressor
See last page for list of abbreviations
Multi-functional DC inverter air/water heat pump
Standard
Range
650 001 330
0: OFF
1: ON
0
0~4
1
0-DHW 1-A/C Heating 2-A/C Cooling
3-DHW+A/C Heating 4-DHW+A/C
Cooling
10~60 °C
45
10~30 °C
12
10-60°C (value ≥ P35, only electrical heater) 50
18~35 °C
21
1~15 K
5
1~15 K
5
35~50 °C
45
-10~10 °C
0
1-99 days
7
1-23 (time)
23
5-99 min.
10
50~75 °C
70
0-Auto 1-manual 2-OFF
0
0-23 (time)
22
0-23 (time)
6
0-OFF 1-ON
0
0-OFF 1-ON
0
0-OFF 1-ON
0
0-without stop, 1-stop when temp.
0
has been reached, 2-runtime: 1
min. every 15 min.
5~50 min
30
-30~20 °C
0
-30~20 °C
0
1~15 °C
2
-15~5 °C
3
0~4
1
0-without defrost, 1~4 multiple
defrost interval time
15-99 min.
35
0-Auto 1-Manual defrost (after
0
defrost back to standard 0)
-8~5 °C
0
5~30 °C
20
2~20 min
15
0-no 1-test chart 2-manual
4
3-suction gas overheating,
4-discharge gas overheating
50-480 (only valid if P32=2)
400
50-480 (only valid if P32=2)
400
0~60 °C
55
Standard
Standard
Standard
6KW
9KW
12KW
18KW
650 001 331
650 001 332
650 001 333
0
0
0
1
1
1
45
45
45
12
12
12
50
50
50
21
21
21
5
5
5
5
5
5
45
45
45
0
0
0
7
7
7
23
23
23
10
10
10
70
70
70
0
0
0
22
22
22
6
6
6
0
0
0
0
0
0
0
0
0
0
0
0
30
30
30
0
0
0
0
0
0
2
2
2
3
3
3
1
1
1
35
35
35
0
0
0
0
0
0
20
20
20
15
15
15
4
4
4
400
400
400
400
400
400
55
55
55