Initial settings
■Station parameter
Setting item
Cyclic data update watch time setting
■Basic module parameter
Setting item
D/A conversion enable/disable setting
Analog output HOLD/CLEAR setting
Alert output function
Scaling function
For the parameters other than the above, use the initial value.
8 PROGRAMMING
80
8.3 Program Example
Downloaded from
ManualsNet.com
CH1 D/A conversion enable/disable setting
CH2 D/A conversion enable/disable setting
CH5 D/A conversion enable/disable setting
CH6 D/A conversion enable/disable setting
CH1 Analog output HOLD/CLEAR setting
CH5 Analog output HOLD/CLEAR setting
CH2 Alert output setting
CH2 Alert output upper limit value
CH2 Alert output lower limit value
CH6 Alert output setting
CH6 Alert output upper limit value
CH6 Alert output lower limit value
CH1 Scaling enable/disable setting
CH1 Scaling upper limit value
CH1 Scaling lower limit value
CH5 Scaling enable/disable setting
CH5 Scaling upper limit value
CH5 Scaling lower limit value
search engine
Setting value
5
Setting value
0: Enable
0: Enable
0: Enable
0: Enable
1: HOLD
1: HOLD
0: Enable
10000
3000
0: Enable
10000
3000
0: Enable
32000
0
0: Enable
32000
0