Specifications
■ Ratings
Power supply voltage
Allowable power supply voltage range
Power consumption
(See note 1.)
Current consumption
Input
A/D conversion method
External power supply
Event inputs
Timing input
(See note 2.)
Startup compensation
timer input
Hold input
Reset input
Forced-zero input
Bank input
Output ratings (depends
Relay output
on the model)
Transistor output
Linear output
Display method
Main functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Accessories
Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend-
ed.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
Thin Cables.
100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
100 to 240 V: 18 VA max. (max. load)
24 VAC/DC: 11 VA/7 W max. (max. load)
DeviceNet power supply: 50 mA max. (24 VDC)
DC voltage
Delta-Sigma method
See Sensor Power Supply/Output Type Codes
NPN open collector or no-voltage contact signal
ON residual voltage: 3 V max.
ON current at 0 Ω : 17 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 1.5 mA max.
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max.
ON current at 0 Ω : 4 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max.
250 VAC, 30 VDC, 5 A (resistive load)
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 µ A max.
Linear output 0 to 20 mA DC, 4 to 20 mA:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 k Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; not output for 0 V or less)
Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)
Scaling function, measurement operation selection, averaging, previous average value comparison, forced-
zero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display
color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset
− 10 to 55 ° C (with no icing or condensation)
25% to 85%
− 25 to 65 ° C (with no icing or condensation)
2,000 m max.
Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual. DeviceNet models also include
a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note
3.)
K3HB-V
Weighing Indicator
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb series

Table of Contents