Omron K35-2 Manual page 27

Digital indicators
Hide thumbs Also See for K35-2:
Table of Contents

Advertisement

■ Main Functions
Measurement
Input Calculation
• Two input circuits are provided. The input ranges for these circuits
can be set independently. For example, one can be set to 4 to 20
mA and the other can be set to 1 to 5 V.
• In addition to calculations such as K (constant)–A (input for one cir-
cuit), it is possible to perform calculations based on the inputs for
both circuits, such as A+B and A–B, making it possible to perform
thickness measurement and level-difference measurement using
displacement and length-measuring sensors.
Timing Hold
Normal
• Continuously performs measurement and always outputs based on
comparative results.
Input
H comparative set value
Measurement value
H output
Peak Hold/Bottom Hold
• Measures the maximum (or minimum) value in a specified period.
Input
Measurement value
TIMING
ON
input
OFF
Scaling
Scaling converts input signals in any way required before displaying
them. The values can be manipulated by shifting, inverting, or +/–
reversing.
Display value
Display value 2
(dsp.a2)
Display value 1
(dsp.a1)
Input value 1
Input value 2
(inp.a1)
(inp.a2)
(Scaling)
Teaching
Settings for scaling can be made using the present measurement
values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making the settings while monitoring the
operating status.
Standby Sequence
26
Digital Indicators
S
X V H S
Peak hold value
Bottom hold value
Time
X V S
Display value
Display value 2
(dsp.a2)
Display value 1
(dsp.a1)
Input value 2
Input value 1
Input value
(inp.a2)
(inp.a1)
(Reverse scaling)
X V S
X V H S
K3HB-X/-V/-H/-S
A
K
Sampling Hold
• Holds the measurement at the rising edge of the TIMING signal.
Input
Measurement value
ON
TIMING
Time
input
OFF
Peak-to-peak Hold
• Measures the difference between the maximum and minimum val-
ues in a specified period.
Input
Measurement value
TIMING
ON
input
OFF
Average Processing
Turns the comparative output OFF until the measurement value
enters the PASS range.
Average processing of input signals with extreme changes or noise
smooths out the display and makes control stable.
Previous Average Value Comparison
Slight changes can be removed from input signals to detect only
extreme changes.
Input value
Temperature Input Shift
Shifts the temperature input value.
Supported Models
The models that support the functions shown here are indi-
cated by symbols as follows:
X
K3HB-X
V
K3HB-V
H
K3HB-H
S
K3HB-S
K−A
Sampling hold value
Peak-to-peak value
(b1−a1)
b1
'b2
a1
'a2
X V H S
X V H S
H
Time
(b2−a2)
Time