■ Characteristics
Display range
Sampling period
Comparative out-
One input
put response
Two inputs
times (transistor
outputs)
Linear output re-
One input
sponse time
Two inputs
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of protec-
Front panel
tion
Rear case
Terminals
Memory protection
Applicable standards
EMC
■ Input Ranges (Measurement Ranges and Accuracy)
Input
Input type
K3HB-SSD
0 to 20 mA
DC voltage/current
4 to 20 mA
input
0 to 5 V
1 to 5 V
±5 V
±10 V
Note: The accuracy is for an ambient temperature of 23±5 ° C.
18
Linear Sensor Indicator
− 19,999 to 99,999
One input: 0.5 ms; Two inputs: 1.0 ms
OFF to ON: 1 ms max., ON to OFF: 1.5 ms max.
OFF to ON: 2 ms max., ON to OFF: 2.5 ms max.
51 ms max.
52 ms max.
20 M Ω min. (at 500 VDC)
2,300 VAC for 1 min between external terminals and case
100 to 240 VAC models:
± 1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µ s/100 ns)
24 VAC/VDC models:
± 1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µ s/100 ns)
Frequency: 10 to 55 Hz; Acceleration: 50 m/s
2
2
150 m/s
(100 m/s
for relay outputs) 3 times each in 3 axes, 6 directions
Approx. 300 g (Base Unit only)
Conforms to NEMA 4X for indoor use (equivalent to IP66)
IP20
IP00 + finger protection (VDE0106/100)
EEPROM (non-volatile memory)
Number of rewrites: 100,000
UL61010C-1, CSA C22.2 No. 1010.1(evaluated by UL)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMI: EN61326+A1 industrial applications
Electromagnetic radiation interference
CISPR 11 Group 1, Class A: CISPRL16-1/-2
Terminal interference voltage
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EMS: EN61326+A1 industrial applications
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz)
Electrical Fast Transient/Burst Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0 ° /180 °, 100% (rated voltage)
Measurement range
Indication range
− 2.000 to 22.000 mA
0.000 to 20.000 mA
4.000 to 20.000 mA
2.000 to 22.000 mA
− 0.500 to 5.500 mA
0.000 to 5.000 V
1.000 to 5.000 V
0.500 to 5.500 V
±5.000 V
± 5.500 V
±10.000 V
± 11.000 V
K3HB-S
2
, 10 sweeps of 5 min each in X, Y, and Z directions
Input
impedance
120 Ω max.
One input:
±
0.1% F.S.
±1 digit max.
1 M Ω min.
Two inputs:
±
0.2% F.S.
±
1 digit max.
Accuracy
Maximum
(at 23 ± 5 ° C)
absolute rated
input
±31 mA
±10 V
±14.5 V