G100 Range Optional Products And Accessories; Optional Products; Analyser Data Manager (Optional); Event Log - LANDTEC Geotech G100 Series Operating Manual

Table of Contents

Advertisement

OMG100N1.21
3.0

G100 Range Optional Products and Accessories

3.1

Optional Products

The G100 analyser range has a number of optional products for purchase which enhance
the usability and enable further analysis of data and reading information.
Note: For more information on the features listed in this section please contact Sales at
Geotech (UK) Limited on +44(0)1926 338111 or email Sales@geotech.co.uk.
3.1.1

Analyser Data Manager (Optional)

Analyser Data Manager enables the user to maximise the operation of the incubator
analyser. Instrument readings and event log data may be downloaded to a PC for further
analysis and exported to other applications such as MS Excel. It enables direct
communication with the unit, features a simple download facility and is fully compatible
with the latest Microsoft operating systems.
3.1.1.1

Event Log

The G100 instruments incorporate the facility to log significant events via the 'Event
Log'. This can be used as an aid to monitoring the use of the instrument. It can also be
used as a diagnostic tool if there is a problem with the instrument.
The event log can only be viewed via the optional Analyser Data Manager software. It
cannot be viewed on the analyser screen. Applicable events are stored in the event log
automatically. No user intervention is required.
The event log can hold approximately 270 events. If the log becomes full then it begins
to over-write the older events. This can be identified by the index field which starts from
event number 1. The log is cleared when the instrument is reset.
Note: Please refer to section '12.0 Event Log' of this operating manual for further
information.
3.1.2

Temperature Probe Reading (Optional)

The G100 range of instruments has the facility to read and display two temperature
readings via optional temperature probes. When a temperature probe is fitted to one of
the two temperature ports on the top of the instrument, the display will automatically
show the current reading and a temperature probe icon will be displayed.
The display can also be changed to show a T
soft-key. The current mode of operation can be identified by normal or inverse status of
the soft-key, where inverse indicates that the option is active.
Note: The T
1
The operator can also choose to display the reading in either Centigrade or Fahrenheit
using the temperature option accessed from the 'Settings' menu.
Page 8
– T
result is not stored as part of the reading.
2
 Copyright Geotechnical Instruments (UK) Limited
– T
calculation by pressing the appropriate
1
2
G100 Range