3.1 Projector Web Control - Port Settings (continued)
Item
SNMP Port
Port open
Trap address
Download MIB file
Network Bridge Port
Port number
Click the [Apply] button to save the settings.
NOTE
• The new configuration settings are activated after restarting the
network connection. When the configuration settings are changed, you must
restart the network connection. You can restart the network connection from
Network Restart on the main menu. (&66)
LWU720i/LHD720i/LWU620i
User's Manual - Network Guide
Configures the mib file port.
Click the [Enable] checkbox to use SNMP.
Configures the destination of the SNMP Trap in IP format.
• The address allows not only IP address but also domain
name if the valid DNS server is setup in the Network
Settings. The maximum length of host or domain name is up
to 255 characters.
Downloads a MIB file from the projector.
Configures the Bridge port number.
Input the port number.
Except for 41794, 9715, 9716, 9719, 9720, 5900, 5500, 4352
between 1024 and 65535 can be set up. It is set to 9717 as
the default setting.
47
Description
020-001293-01 Rev. 1 (10-2017)
3. Web Control