Tracking Generator
N:\mkt\MANUALS\HP8924C\ALR\specs.fb
Non-harmonic Spurious Responses
> 70 dB (for input signals ≤ −30 dBm).
Level Accuracy
± 2.5 dB.
Log Scale Linearity
± 2 dB (for input levels ≤ −30 dBm and/or 60 dB range).
Displayed Average Noise Level
< −114 dBm (≤ 50 kHz spans).
Other Features
Peak hold.
Marker with frequency and level readout.
Marker to peak.
Marker to next peak.
Trace comparison A-B.
Frequency Range
30 MHz to 1000 MHz.
Frequency Offset
Frequency span endpoints ± frequency offset cannot be < 30 MHz or > 1000 MHz.
Output Level Range
Same as signal generator.
Sweep Modes
Normal and Inverted.
Spectrum Analyzer Specifications (HP 8924E: Option 102 required)
Chapter 9, HP 8924C/E Specifications