FM Measurement
N:\mkt\MANUALS\HP8924C\ALR\specs.fb
Frequency Range
30 to 1000 MHz
Deviation Range
20 Hz to 75 kHz.
Sensitivity (15 kHz IF BW, High Sensitivity Mode, 0.3 to 3 kHz BW)
2 µV. Typically < 1 µV (12 dB SINAD, fc ≥ 10 MHz).
Accuracy (20 Hz to 25 kHz rates, deviation ≤ 25 kHz)
± 4% of reading plus residual FM and noise contribution.
Bandwidth (3 dB)
2 Hz to 70 kHz (DCFM measurements also available).
THD+Noise
< 1% for ≥ 5 kHz deviation and 1 kHz rate in a 0.3 to 3 kHz BW.
Input Level Range for Specified Accuracy
−28 to +35 dBm at RF IN/OUT (1.6 µW to 3W).
−50 to +14 dBm at ANT IN.
Residual FM and Noise (0.3 to 3 kHz, rms)
< 7 Hz.
Resolution
Deviation < 10 kHz: 1 Hz.
Deviation. ≥ 10 kHz: 10 Hz.