Chapter 5, HP 8924C Performance Verification
RF Gen Duplex Output Low Level Accuracy Performance Test 6
NOTE:
Make sure to enter the power sensor's calibration data into the measuring receiver and zero
the power sensor. Refer to the measuring receiver's operating manual. The procedure for
making tuned RF level measurements is also in the measuring receiver's manual.
Procedure
Level (dBm) RF Freq (MHz)
164
1. Access the CONFIGURE screen.
2. Change the RF Display field to Freq.
3. Select the RF GENERATOR screen.
4. Set the Output Port field to Dupl
5. Set the AFGen1 To and AFGen2 To fields to Off
RF GENERATOR
TX Frequency
TX Power
RF Gen Freq
AFGen 1 Freq
Amplitude
AF Gen1 To
Atten Hold
FM Coupling
Output Port
Select Dupl
6. Measure the RF level at the frequencies and levels shown in the PTR
Duplex Output Low Level Accuracy Performance Test 6" on page
compare measured RF level to the limits shown in the PTR.
AC Level
AFGen2 Freq
Mic Pre-Emp
To Screen
AFGen2 To
Mod In To
Audio Out
Select Off
(see "RF Gen
315) and