Safety equipments: Door switch and safety
switch (e.g. Harvia SFE)
Remote control: Short circuit connection (ON/
OFF)
Additional equipment control: Max 100 W, 230
V 1N~. It is possible to control e.g. electric
locks, electric heating or indicator lights.
Sensors:
The temperature sensor is equipped with a re-
settable overheat protector and a temperature-
sensing NTC thermistor (22 kΩ/T=25 °C).
Weight: 175 g with cable (ca 4 m)
Dimensions: 51 mm x 73 mm x 27 mm

1.3. Troubleshooting

If an error occurs, home window will illuminate an
error message symbol
message E (number) will be displayed. Table 1.
Note! All service operations must be done by pro-
fessional maintenance personnel. No user-service-
able parts inside.
22
and by pressing that error
DE
400 V 3N~
Sicherheitsvorrichtungen: Türschalter und Si-
cherheitsschalter (z. B. Harvia SFE)
Fernbedienung: Kurzschlussverbindung (EIN/AUS)
Steuerung von zusätzlicher Ausrüstung: max.
100 W, 230 V 1N~. Es können beispielsweise
elektrische Verriegelungen, elektrische Heizung
oder Kontrolllampen gesteuert werden.
Fühler:
Der Temperaturfühler ist mit einem rücksetz-
baren Überhitzungsschutz und einem NTC-
Thermistor zur Temperaturerfassung ausges-
tattet (22 kΩ/T=25 °C).
Gewicht: 175 g mit Kabel (ca. 4 m)
Abmessungen: 51 mm x 73 mm x 27 mm
1.3. Störungsbeseitigung
Wenn ein Fehler auftritt, wird im Startfenster ein
Fehlermeldungssymbol
Drücken auf dieses Fehlersymbol wird „F" und eine
Nummer angezeigt. Tabelle 1.
Achtung! Alle Wartungsmaßnahmen müssen von
qualifiziertem technischem Personal durchgeführt
werden. Es befinden sich keine vom Benutzer zu
wartenden Teile im Gerät.