Wiring
2.1.2
Connection of accessory optional brake resistor
Connecting the brake resistor enclosed with the unit to the FR-A760-00017 to 00061 will improve regeneration
capability.
(1) Installation procedure
Connect the brake resistor to the inverter with accessory screws.
2
REMARKS
Connecting the brake resistor changes the protective structure to OPEN type (NEMA1).
(2) Connection
Wiring cover and Handling (FR-A760-00061 or less)
1) Remove the wiring cover of the inverter. Punch out a knockout by firmly tapping it with such as a hammer. Remove
any sharp edges and burrs from knockout holes of the wiring cover.
Wiring cover
15