Parameter List
Func-
Parameter
tion
807
Speed limit selection
808
Forward rotation speed limit
809
Reverse rotation speed limit
810
Torque limit input method selection
811
Set resolution switchover
812
Torque limit level (regeneration)
813
Torque limit level (3rd quadrant)
814
Torque limit level (4th quadrant)
815
Torque limit level 2
816
Torque limit level during acceleration
817
Torque limit level during deceleration
Easy gain tuning response level
818
setting
819
Easy gain tuning selection
820
Speed control P gain 1
821
Speed control integral time 1
822
Speed setting filter 1
823
Speed detection filter 1
*4
824
Torque control P gain 1
825
Torque control integral time 1
826
Torque setting filter 1
827
Torque detection filter 1
828
Model speed control gain
830
Speed control P gain 2
831
Speed control integral time 2
832
Speed setting filter 2
833
Speed detection filter 2
*4
834
Torque control P gain 2
835
Torque control integral time 2
836
Torque setting filter 2
837
Torque detection filter 2
840
Torque bias selection
*4
841
Torque bias 1
*4
842
Torque bias 2
*4
843
Torque bias 3
*4
844
Torque bias filter
*4
845
Torque bias operation time
*4
846
Torque bias balance compensation
*4
847
Fall-time torque bias terminal 1 bias
*4
848
Fall-time torque bias terminal 1 gain
*4
849
Analog input offset adjustment
850
Brake operation selection
853
Speed deviation time
*4
854
Excitation ratio
858
Terminal 4 function assignment
859
Torque current
860
Second motor torque current
862
Notch filter time constant
863
Notch filter depth
864
Torque detection
865
Low speed detection
68
Name
0, 1, 2
0 to 120Hz
0 to 120Hz, 9999
0, 1
0, 1, 10, 11
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 400%, 9999
1 to 15
0 to 2
0 to 1000%
0 to 20s
0 to 5s, 9999
0 to 0.1s
0 to 200%
0 to 500ms
0 to 5s, 9999
0 to 0.1s
0 to 1000%
0 to 1000%, 9999
0 to 20s, 9999
0 to 5s, 9999
0 to 0.1s, 9999
0 to 200%, 9999
0 to 500ms, 9999
0 to 5s, 9999
0 to 0.1s, 9999
0 to 3, 9999
600 to 1400%, 9999
600 to 1400%, 9999
600 to 1400%, 9999
0 to 5s, 9999
0 to 5s, 9999
0 to 10V, 9999
0 to 400%, 9999
0 to 400%, 9999
0 to 200%
0, 1
0 to 100s
0 to 100%
0, 1, 4, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 60
0, 1, 2, 3
0 to 400%
0 to 400Hz
Minimum
Setting Range
Setting
Increments
1
0.01Hz
0.01Hz
1
1
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
1
1
1%
0.001s
0.001s
0.001s
1%
0.1ms
0.001s
0.001s
1%
1%
0.001s
0.001s
0.001s
1%
0.1ms
0.001s
0.001s
1
1%
1%
1%
0.001s
0.01s
0.1V
1%
1%
0.1%
1
0.1s
1%
1
0.01A/0.1A
*2
0.01A/0.1A
*2
1
1
0.1%
0.01Hz
Refer
Customer
Initial Value
to
Page
0
113
60
Hz
113
9999
113
0
86
86,
0
237
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
2
91
0
91
60%
91
0.333s
91
9999
277
0.001s
130
100%
116
5ms
116
9999
277
0s
130
60%
98
9999
91
9999
91
9999
277
9999
130
9999
116
9999
116
9999
277
9999
130
9999
100
9999
100
9999
100
9999
100
9999
100
9999
100
9999
100
9999
100
9999
100
100%
277
0
190
1s
103
100%
131
0
270
9999
176
*2
9999
176
*2
0
104
0
104
150%
235
1.5Hz
232
Setting