Mitsubishi Electric FR-A760 Series Instruction Manual page 242

Table of Contents

Advertisement

(5) Fault output signal (ALM, ALM2 signal)
Inverter fault occurrence (trip)
ON OFF
ALM
ON
ALM2
ON OFF
RES
Reset processing
Reset ON
(6) Input MC shutoff signal (Y91 signal)
⋅ The Y91 signal is output at occurrence of a fault attributable to the failure of the inverter circuit or a fault caused by
a wiring mistake.
⋅ When using the Y91 signal, set "91 (positive logic)" or "191 (negative logic)" to any of Pr. 190 to Pr. 196 (output
terminal function selection) to assign the function to the output terminal.
⋅ The following table indicates the faults that will output the Y91 signal. (Refer to page 390 for the fault description.)
No.
1
Inrush current limit circuit fault (E.IOH)
2
CPU error (E.CPU)
3
CPU error (E.6)
4
CPU error (E.7)
5
Parameter storage device fault (E.PE)
6
Parameter storage device fault (E.PE2)
7
24VDC power output short circuit (E.P24)
Operation panel power supply short circuit, RS-485 terminal
8
power supply short circuit(E.CTE)
9
Output side earth(ground) fault overcurrent protection(E.GF)
10
Output phase loss (E.LF)
11
Brake transistor alarm detection (E.BE)
♦ Parameters referred to ♦
Pr. 13 Starting frequency
Refer to page 163 .
Pr. 76 Fault code output selection
⋅ If the inverter comes to trip, the ALM and ALM2 signals are
⋅ The ALM2 signal remains on during a reset period after fault
⋅ When using the ALM2 signal, set "94 (positive logic)" or "194
Time
OFF
⋅ The ALM signal is assigned to the A1B1C1 contact in the
(about 1s)
Fault Description
Refer to page 259
Function assignment of external terminal and control
output.
occurrence.
(negative logic)" to any of Pr. 190 to Pr. 196 (output terminal
function selection) to assign the function to the output
terminal.
initial setting.
REMARKS
Refer to page 390 for the inverter fault description.
4
231

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents