Download Print this page

Oxgard Praktika T-04 Maintenance Operations

Speedgate
Hide thumbs Also See for Praktika T-04:

Advertisement

Quick Links

MAINTENANCE
OPERATIONS
Praktika T-04(K) speedgate
www.oxgard.com
info@oxgard.com
Tel.+7(812) 366-15-94

Advertisement

loading
Need help?

Need help?

Do you have a question about the Praktika T-04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Oxgard Praktika T-04

  • Page 1 MAINTENANCE OPERATIONS Praktika T-04(K) speedgate www.oxgard.com info@oxgard.com Tel.+7(812) 366-15-94...
  • Page 3: Table Of Contents

    Content 1. General information ..................4 2. Conditions for maintenance ................5 3. Partial disassemble of the speedgate ............. 5 4. Checking speedgate parts ................6 5. Speedgate lubrication .................. 10 6. Assembling and operation checking of the speedgate ........ 10 Maintenance operations...
  • Page 4: General Information

    1.4. MO includes the following scope of work: partial disassemble of the speedgate, cleaning of load-bearing frame, checking of parts and units fixation, lubrication of subject to wear parts of actuating device, checking of belt tension, setting the dismantled parts and a general inspection of the speedgate. Praktika T-04(K) speedgate...
  • Page 5: Conditions For Maintenance

    2. Conditions for maintenance CAUTION! It is strictly forbidden to carry out work with powered speedgate. Failure to follow these safety requirements could result in damage to human life and health, total or partial loss of product workability and (or) auxiliary equipment. CAUTION! It is not recommended to adjust the limitation units of solenoid stroke, Hall sensor bracket and spring tension.
  • Page 6: Checking Speedgate Parts

    4.3. If necessary check and tighten the screw joints of speedgate: - fixation of speedgate housing to the base; - fixation of wings on brackets; - fastening of a locking screw on the lower bracket of wing (Fig. 2); Praktika T-04(K) speedgate...
  • Page 7 Fig.2 . 4.4. Check the condition of the toothed belt and its tension (Fig. 3). Correctly tensioned belt should be rotated through an angle of 45 from the fingers effort (1.5-2.0 kg / 15-20 N) (Fig. 4). Maintenance operations...
  • Page 8 Fig. 3 Fig. 4 The belt tension can be changed by moving the motor frame on right/left (Fig. 5). Praktika T-04(K) speedgate...
  • Page 9 Fig. 5 Fig. 6 Speedgate housing Maintenance operations...
  • Page 10: Speedgate Lubrication

    6.2. Reassemble the speedgate in reverse order. 6.3. Turn on the speedgate and check functionality. 6.4. If there is no extraneous noise or any abnormality in the speedgate work it is ready for operation. Praktika T-04(K) speedgate...
  • Page 11 Maintenance operations...
  • Page 12 OOO "Vozrozdenie" 192289 Saint Petersburg Sofiyskaya st., 66 Tel./fax +7 (812) 366 15 94 www.oxgard.com info@oxgard.com...