Oxgard Praktika T-03-M Installation Manuallines

Oxgard Praktika T-03-M Installation Manuallines

Hide thumbs Also See for Praktika T-03-M:

Advertisement

Quick Links

Installation
guidelines
Praktika T-03-M(K) turnstile
www.oxgard.com
info@oxgard.com
Тел.+7(812)366-15-94

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Praktika T-03-M and is the answer not in the manual?

Questions and answers

Summary of Contents for Oxgard Praktika T-03-M

  • Page 1 Installation guidelines Praktika T-03-M(K) turnstile www.oxgard.com info@oxgard.com Тел.+7(812)366-15-94...
  • Page 3: Table Of Contents

    Contents 1. Basic specifications ..................5 2. Product design ....................6 4. Installation of turnstile ................10 4.1. Required equipment ................10 4.2. Installation of turnstile ................ 11 5. Connecting turnstile ................... 15 5.1. Connecting power supply ..............19 5.2. Connecting remote control panel ............19 5.3.
  • Page 4 List of abbreviations – power supply – fire alarm – remote control – access control system – operating device (turnstile) – normally connected – normally opened Turnstile firmware version FW v1.76 Card collector firmware version FW v1.52 Praktika T-03-M(K) turnstile...
  • Page 5: Basic Specifications

    1. Basic specifications Table 1 Basic specifications Description Turnstile RC panel Dimension (HхWхL), (mm) 107х107х25 1505х1200х1730 - operational state - collapsed arms 1505х1200х730 Weight, kg 176,0 Temperature range, 0C - operation +1...+40 +1...+40 - transportation and storage +1...+40 +1...+40 Atmosphere relative humidity, no more than Passage width, mm 2x500 Throughput, people per minute...
  • Page 6: Product Design

    PS, RC and ACS cables are connected. In the lower part there are holes for cable routing and base cover concealing the fixation of turnstile to the floor (Fig. 1). Praktika T-03-M(K) turnstile...
  • Page 7 Fig. 1 General view of turnstile Display system Display system turnstile consists of four panels. The panels are made of artificial stone with insertions made of acrylic glass. Turnstile operating modes are displayed on the panel in the form of mnemonic signs depicting authorization and non-authorization of passage (Fig.
  • Page 8 Remote Control Panel The housing of RC is made of polished stainless steel. On the front side there are control buttons and LED indicators of RC operational modes (Fig. 4). The standard supplied cable is 5 meters long. Praktika T-03-M(K) turnstile...
  • Page 9 Fig. 4 General view of remote control 3. Safety requirements CAUTION! Failure to comply with the safety requirements specified in this section may result in damage to human life and health, total or partial loss of workability of products and (or) auxiliary equipment. CAUTION! Installation of turnstile must be carried out by qualified personnel according to the instructions.
  • Page 10: Installation Of Turnstile

    Tools used for turnstile mounting: • electric perforator; • 20mm diameter carbide drill for drilling holes in the floor for anchors (recommended anchor - SORMAT PFG LB 12-50); • S10 wrench for hexagon socket head screws; • slotted screwdriver; Praktika T-03-M(K) turnstile...
  • Page 11: Installation Of Turnstile

    • plumb line or level; • steel liner for turnstile alignment • round file • side cutters 4.2. Installation of turnstile CAUTION: When designing the mounting site of the turnstile take into account that rotation direction of arms will be counter-clockwise during "antipanic"...
  • Page 12 (3, Fig. 6) 4.2.8. In order to route cables into the side stand with card collector, undo four self-tapping screws (5, Fig. 6), and lift the base housing (4, Fig. Praktika T-03-M(K) turnstile...
  • Page 13 6). Unblock the lock of card collector housing (6, Fig. 6) and open the hatch (7, Fig. 6). 4.2.9. Route into turnstile housing RC and PC cables and, if necessary, FA and ACS cables. Cable routing shall be performed via holes of 40 mm and 32 mm diameter in the lower plate of turnstile (Fig.
  • Page 14 Fig. 6 Installation diagram of turnstile Praktika T-03-M(K) turnstile...
  • Page 15: Connecting Turnstile

    5. Connecting turnstile Connection of RC, PS and ACS is performed with the use of motherboard. Both tripods must be connected. In order to do it, open turnstile hatch (1, Fig. 6) with a key. Fig. 7 shows the location of motherboard in the housing.
  • Page 16 Mounting of indication bus lines for the right-hand use of reader. In the second case, the indication bus lines are routed as shown in Fig. 9. Indication bus lines are routed inside central turnstile’s housing, on the horizontal base and sides stands of the turnstile. Praktika T-03-M(K) turnstile...
  • Page 17 Fig. 9 Mounting of indication bus lines for the left-hand use of reader. Fig. 10 shows the appearance of motherboard and connectors for PS unit, RC panel, ACS and FA. Installation guidelines...
  • Page 18 Status of the buttons is transmitted to the outputs I / O1 ... I / O4 (see. 5.4) - Jumper J3 is not used - Jumper J4 is used to establish the normal operation of CAN2.0 bus. See Appendix 1. Praktika T-03-M(K) turnstile...
  • Page 19: Connecting Power Supply

    5.1. Connecting power supply CAUTION! Do not use power supplies with an output current less than Do not install the power supply at a distance more than 25 meters from the turnstile. CAUTION! Do not use power cable with cross-section less than 1.5 mm for connection.
  • Page 20: Connecting Access Control System (Optional)

    Inputs for connecting of ACS differ on priorities: AP input has the highest priority. As long as this input is closed GND contact, arms of the turnstile are collapsed and the turnstile does not respond (!!!) to other signals; Praktika T-03-M(K) turnstile...
  • Page 21 STOP input has the medium priority. When the input is closed on GND contact the turnstile switches to "Stop" and does not respond to other effects, except AP. LEFT and RIGHT inputs have the same low priority and include a single passage in one direction or another.
  • Page 22 Jumper J4 shall be installed. It is used to connect a 120 Ohm resistor ensure normal operation. If two remote control panels are used J4 shall not be installed, because 120 Ohm resistors are installed on CL and CH contacts in remote control panels Praktika T-03-M(K) turnstile...
  • Page 23: Connecting Remote Control Panel To Acs Controller

    5.4. Connecting remote control panel to ACS controller In some cases RC shall be connected directly to the ACS controller as the passages allowed from the remote (without controller) are regarded by the system as a "forced entry". To use this connection pattern of turnstile J2 jumper shall be set on the motherboards (Fig.
  • Page 24 Fig. 12 Connection of diode in parallel with the relay coil Connection of RC panel to ACS controller is shown in Fig. 13. In this case the controller controls the turnstile via "Left", "Right" and "Stop" contacts, Praktika T-03-M(K) turnstile...
  • Page 25 and the contact "antipanic" is turned on and off with the RC panel. Please note that when the RC panel is connected via ACS controller it is impossible to use turnstile modes which are set by the combination of the RC panel buttons (except for the free passage in the potential control mode.
  • Page 26: Connecting Card Collector

    In front of the housing there is a hatch with lock for quick access to collected cards and to the board when PS, OD and ACS cables are connected (Fig. 14). The hatch includes a card storage device. Fig. 14 General view of card collector Praktika T-03-M(K) turnstile...
  • Page 27 ATTENTION (!) Card reader is not included in the delivery set. Customer can choose reader model suitable for the existing system. The reader is mounted on a universal adjustable bracket, located under the top cover of the card collector. This solution provides maximum flexibility for installation and connection of the card collector.
  • Page 28: Connecting Power Supply

    6.3.1. "Let Go" contact set NC, NO, and COMM contacts. Relay output operating on a "dry contact" principle, which closes / opens, transmitting passage authorizing signal to OD. NC and COMM - normally closed connection, NO and COMM- normally open connection. Praktika T-03-M(K) turnstile...
  • Page 29: Connecting Acs Controller

    6.3.2. "Pass Ok-GND" contact set Pass Ok and GND contacts. Pulse input that receives a signal from OD, confirming that the passage was performed. The operating principle is based on normally open contacts. Passage is detected by a contact closure for at least 200 ms.
  • Page 30 (see. Article 6.3.1). In this case a green arrow indicator on the LED panel turns on. Free Pass input of the card collector shall operate in pulse mode (activation upon contact closure). In pulse mode the voltage is applied to Praktika T-03-M(K) turnstile...
  • Page 31 Free Pass input for a short moment and it authorizes the passage. Another passage becomes non-authorized when the passage is performed or after 5 seconds. Pulse mode is set by default, in such case the card collector provides 1 audio signal upon turn-on. If the card collector provides 2 audio signals, it means that it is set in potential mode.
  • Page 32: Installation Of Proximity Card Reader

    As an example of installation reader of contactless cards MatrixIII is used. Installation of other models of readers may be different from the presentation. 6.5.1. Undo the M4 screw at the rear of the card collector (Fig. Fig. 18 Praktika T-03-M(K) turnstile...
  • Page 33 6.5.2. Slide the LED panel to the stop in the direction indicated in Fig. 16. Carefully lift the panel. 6.5.3. Remove two M4 screws (8, Fig. 19) and remove the universal bracket for readers (2, Fig. 19). 6.5.4. Disassemble the reader, removing the M3 screw (6, Fig. 18), and set its lower part (1, Fig.
  • Page 34 Fig. 19. Installation of proximity card reader Fig. 20 Recommended option for card reader installation Praktika T-03-M(K) turnstile...
  • Page 35 Appendix 1. Summary of the data bus CAN2.0 The RC panel uses modern CAN2.0 noise-immune bus. According to CAN2.0 standard signal cable length can exceed one kilometer, however correct operation on these distances depends on many factors. Always use Cat5e or Cat6 twisted pair at distances exceeding 25 meters. The total electrical resistance of DC power supply wire shall not exceed 50 ohms.
  • Page 36 1* and 2* are drawn by dotted lines. This scheme features two readers. The second reader shall be installed outside the card collector, which is not always aesthetically and practically acceptable. If installed close to each other, proximity readers can create mutual interference. Praktika T-03-M(K) turnstile...
  • Page 37 Fig. 22 Block diagram №2 Fig. 22 shows a more advanced but also a more high-cost circuit connection. The advantage of this scheme is that it uses only one reader installed in the card collector. Wiegand interface provides a possibility to connect several identical ACS controllers to one reader in parallel.
  • Page 38 #2. It reduces the cost of installed system. For this purpose the controller with two output signals to one input of a reader (i.e., the controller can distinguish the guest cards and permanent cards transmitting a signal to the corresponding output) is used. Praktika T-03-M(K) turnstile...
  • Page 39 Appendix 3. Location of mounting holes in relation to the overall dimensions of the turnstile Fig. 24 Location of mounting holes in relation to the overall dimensions of the turnstile Installation guidelines...
  • Page 40 Praktika T-03-M(K) turnstile...
  • Page 41 Installation guidelines...
  • Page 42 Praktika T-03-M(K) turnstile...
  • Page 43 Installation guidelines...
  • Page 44 OOO "Vozrozdenie" 192289 Saint Petersburg Sofiyskaya st., 66 Tel./fax +7 (812) 366 15 94 www.oxgard.com info@oxgard.com...

This manual is also suitable for:

Praktika t-03-kPraktika t-03

Table of Contents