TABLE OF CONTENTS Description and operation ......................4 1.1 Product description and operation ..................4 1.2 Description and operation of Oxgard Praktika control panel ..........10 Intended use ..........................11 2.1 Operating limits ........................11 2.2 Preparing the product for use ....................12 2.3 Product operation .........................
Page 3
VZR.249600.000OM This Operation Manual (OM) applies to Oxgard Cube C-10 full height rotor turnstile and its modifications (hereinafter referred to as the product). Product firmware version: FС C-10 The manufacturer reserves the right to change configuration, technical characteristics and appearance of the product without further notice Before using the product, please read the Logbook VZR.249600.000 LB as...
To ensure convenient and fast passage of people, it is recommended to install one product per 300 people working during one shift. 1.1.2 The product structure is provided in Table 1. Cube C-10 full height rotor turnstile Operation Manual...
Page 5
UCP 02* Universal control panel 02 Reader for PC* Z2-USB Barrier section set* Praktika barrier Bracket* Fastening bracket to turnstile Key for unlocking lock Note - Product components marked with (*) are optional. Cube C-10 full height rotor turnstile Operation Manual...
Page 6
Maximum number of connected control panels, pcs. Width of blocked passage, mm 1455 Number of rotor blades, pcs. Number of horizontal rods in blade, pcs. Length of rotor blade rod, mm Passage height, mm 2015 Service life, years Cube C-10 full height rotor turnstile Operation Manual...
Page 7
(color as selected). Figure 1 – General view of the turnstile The turnstile consists of: fixed fencing panel (Figure 1 – 1); moving fencing elements – rotor gate (Figure 1 – 2); Cube C-10 full height rotor turnstile Operation Manual...
Page 8
Figure 2 – initial position of the flaps: – when the turnstile is in initial state, passage area is covered by one panel without forming a gateway; Figure 2 – Initial position of the flaps Cube C-10 full height rotor turnstile Operation Manual...
Page 9
Appearance of the indication panel Marking contains manufacturer’s trademark, designation, and 1.1.6 serial number. 1.1.7 Overall dimensions of the packaging container are: box No. 1 (HхWхL) 420Х1070Х1500; box No. 2 (HхWхL) 565Х890Х2130. Cube C-10 full height rotor turnstile Operation Manual...
VZR.249600.000OM Description and operation of Oxgard Praktika control panel Universal Oxgard Praktika control panel is designed for controlling Oxgard turnstiles. 1.2.1 The housing is made of stainless steel and the control buttons and operating mode LED indicators are located on the front side. The specifications are given in Table 3.
USER FAILS TO COMPLY WITH THE SAFETY REQUIREMENTS SPECIFIED IN THIS SECTION, AND ALSO VOIDS THE PRODUCT WARRANTY. DO NOT: OPERATE THE TURNSTILE IN CONDITIONS NOT MEETING THE REQUIREMENTS TO THE OPERATING CONDITIONS. Cube C-10 full height rotor turnstile Operation Manual...
TURNSTILE ELEMENTS ROTATION AREA FROM PEOPLE AND FOREIGN OBJECTS. 2.2.2 Rules and procedures for visual inspection of the product Visual inspection of the product before connecting it to the mains shall be obligatory and include: Cube C-10 full height rotor turnstile Operation Manual...
Page 13
An indication blinks on the turnstile indication panel indicating the side to which the turnstile must be turned to reach the zero position. Cube C-10 full height rotor turnstile Operation Manual...
Page 14
The turnstile is ready to work. Check the product operation in all modes. 2.2.4 Control panel appearance Figure 5 – control buttons 1 (LEFT), 2 (STOP), 3 (RIGHT), 4 (ANTIPANIC) and LED indicators of the product operating modes. Cube C-10 full height rotor turnstile Operation Manual...
Work with ACS is considered in the Installation Manual. 2.3.2 Controlling the product using the control panel Figure 5 – over each CP button, there is a LED indicator that displays the turnstile operating mode. Cube C-10 full height rotor turnstile Operation Manual...
Page 16
It is also possible to authorize a single pass into the non-authorized direction by pressing button 1 (3). The product will return to the original mode after this passage or within 8 seconds. Cube C-10 full height rotor turnstile Operation Manual...
Page 17
Table 4 – Turnstile settings using UCP 02 Function or operating mode Buttons combination Free passage to the left Short synchronous pressing (2-3 sec) Left Stop Free passage to the right Short synchronous pressing (2-3 sec) Stop Right Cube C-10 full height rotor turnstile Operation Manual...
ELECTRIC CIRCUIT CAN BE A SOURCE OF FIRE DANGER IN CASE OF SHORT CIRCUIT, INSULATION BREAKDOWN AND SPARKING. In case of fire, switch external power supply off. Use powder extinguishers to extinguish fire in the product, wiring and cables. Cube C-10 full height rotor turnstile Operation Manual...
3, and who have read and understood this Operation Manual. Safety precautions When performing maintenance, safety measures shall be observed. Maintenance shall be performed by specially trained technical personnel. Cube C-10 full height rotor turnstile Operation Manual...
Product maintenance procedure Maintenance includes the following scope of work: visual inspection of the product condition; partial disassembly of the turnstile, cleaning of the supporting frame; checking fastening parts and assemblies of the turnstile; Cube C-10 full height rotor turnstile Operation Manual...
Clean inner parts of the upper module from dirt. 3.6.3 Check that all cables are securely attached. 3.6.4 Check and, if necessary, tighten threaded connections of the fasteners of the turnstile assemblies. Cube C-10 full height rotor turnstile Operation Manual...
‘Anti- panic’ mode. If extraneous noise and any violations of operating modes are absent, the turnstile is ready for operation. Cube C-10 full height rotor turnstile Operation Manual...
Page 24
List of addresses of official distributors and service centers is given in Appendix A and is also available at the website: www.oxgard.ru If it is necessary to repair (for T-10 product only) damaged painted surfaces, use powder paint identical to the damaged one (RAL9005) in accordance with the paint instructions for application.
If any other problems occur, contact service department. Routine repairs of the product components Routine repairs of the product components shall be carried out by replacing faulty parts with known good ones. When such replacement is impractical or there Cube C-10 full height rotor turnstile Operation Manual...
VZR.249600.000 LB), please send a claim to the manufacturer. To do this: prepare a technically substantiated Claim Report; make extracts from the LB section “Repair”. make extracts from the LB section “Preservation”. Cube C-10 full height rotor turnstile Operation Manual...
The product shall be stored in dry (without moisture condensation) rooms at a temperature from -40 to + 50 °C. The storage room should be free of acid or alkali vapors, or corrosive gases. Cube C-10 full height rotor turnstile Operation Manual...
When transporting and storing products on Euro pallets, it is allowed to stack boxes in 2 rows. Loading and unloading operations should be carried out in compliance with safety regulations. Cube C-10 full height rotor turnstile Operation Manual...
Examples of such disposal can be product disassembly (dismantling) and sorting its components into groups of similar parts, converting the product into a learning aid or using for purposes other than intended use. Cube C-10 full height rotor turnstile Operation Manual...
Page 34
Dealer www.grumant.ru krim1@grumant.ru krim2@grumant.ru Dealer 644046, Omsk, Mayakovsky st., 14 Modus Trade LLC 7 (3812) 51-00-93 7 (3812) 51-07-29 Table 7 – Foreign distributors and service centers Item Company Contact details Status Cube C-10 full height rotor turnstile Operation Manual...
Page 35
Minsk, Petr Glebka st., 1 Dealer Systems Unitary 375 (17) 390-66-66 (multi-line) Service center Enterprise Mob.: +375 (33) 340-11-11 (MTS) www.sob.by info@sob.by Mustamäe tee 102-106 Tallinn Harjumaa 12917 OÜ Almasel Service center Tel +372 59192909 info@almasel.com Cube C-10 full height rotor turnstile Operation Manual...
Need help?
Do you have a question about the CUBE C-10 and is the answer not in the manual?