THE MANAGER30
The Manager30 Battery Management System is a complete charging solution for your
Lead Acid or LiFePO
AC and 12/24V DC inputs to provide a 12V charging output at a maximum 30A rating.
The system also includes a Remote Monitor which provides information such as current,
voltage and temperature as well as a simplified battery percentage and charge rate.
WARNINGS & SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains IMPORTANT SAFETY INSTRUCTIONS for The
Manager30 battery management system.
The unit, Model Number:
recorded in the spaces provided and can be located on the product mounting plate.
DO NOT OPERATE THE BATTERY CHARGER UNLESS YOU HAVE READ AND UNDERSTOOD THIS MANUAL
AND THE CHARGER IS INSTALLED AS PER THESE INSTALLATION INSTRUCTIONS. IT IS REQUIRED THAT
THIS UNIT BE INSTALLED BY QUALIFIED PERSONNEL.
RISK OF EXPLOSIVE GASES:
WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE
GASES DURING NORMAL OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT YOU
FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER.
1.
The Battery Charger should not be used by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they are supervised or have been instructed on how to
use the appliance by a person responsible for their safety. Children should be supervised to ensure that they do
not play with the Battery Charger.
2.
Do NOT alter or disassemble the Battery Charger under any circumstances. All services or repairs must be
returned to REDARC for repair. Incorrect handling or reassembly may result in a risk of electric shock or fire and
may void the unit warranty.
3.
Use of an attachment not recommended or sold by REDARC may result in a risk of fire, electric shock, or injury to
persons.
4.
The AC power connection must be connected to an earthed socket outlet. Do not use the AC input if the cord is
damaged. Use of a non-genuine or damaged AC input cord may result in a risk of fire, electric shock, or injury
to persons. (If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or service agent).
5.
Cable and fuse sizes are specified by various codes and standards which depend on the type of vehicle the Battery
Charger is installed into. Selecting the wrong cable or fuse size could result in harm to the installer or user and/or
damage to the Battery Charger or other equipment installed in the system. The installer is responsible for ensuring
that the correct cable and fuse sizes are used when installing this Battery Charger.
6.
When charging a battery, make sure the settings at the Battery Setup menu on the Remote Monitor are correct for
the type of battery under charge. Charging a battery with the wrong profile may cause the Battery Charger to indicate
a fault or give misleading results and cause injury to persons, damage to the Battery Charger and/or property.
Noticeable oscillations between Boost and Absorption stages indicate the wrong choice of battery type. Check and
adjust battery type. If you are unsure of the battery type or settings to use, set to the Gel setting.
7.
Only use the Battery Charger for charging Standard Automotive Lead Acid, Calcium Content, Gel, AGM, SLI, Deep
Cycle or Lithium Iron Phosphate type 12V batteries.
SAL.FOR.Instruction Manual.BMS1230S2-NA – Version 2
Auxiliary or House battery. The system incorporates 12V Solar, 110V
4
& Serial Number:
1
should be