Redarc BMS1230S2-NA Manual page 31

Battery management system
Table of Contents

Advertisement

3
USER GUIDE
The Load Disconnect setting will output a GROUND relay trigger signal based
on a user set SOC or voltage level.
Disconnect Trigger Screen
Advanced Settings Screen
The Disconnect Trigger setting can be set to Disconnect (Loads OFF),
Connect (Loads ON) or to operate from either SOC or Voltage level triggers.
If either Voltage or SOC are selected at the Disconnect Trigger setting
screen the Disconnect trigger level will need to be selected.
Once the Disconnect trigger level is selected the Reconnect trigger
level must be selected. Note that there is a built in minimum hysteresis
constraint on this setting and a non-adjustable time delay exists to stop
repetitive switching.
Should the Load Disconnect feature be triggered the Remote Monitor will
prompt the user to allow the Loads to be reconnected for 10 minutes.
This allows the user to temporarily use power (for loads such as lighting)
to rectify any issues and/or engage another charging source. After this
time has lapsed the load will disconnect and the prompt will reappear,
unless the battery voltage is above the Disconnect level.
Load
Disconnected
Load Temporarily
Connected
The DC Input Trigger allows you to select whether you would like your DC input to
be triggered via Ignition, automatically via The Manager30, or at a specific voltage.
Set DC Input Trigger Screen
Advanced Settings Screen
Next Menu Item
Back
Next Menu Item/Confirm
Back/Cancel
Turn Loads ON for 10 mins
No
30
Low Voltage Alarm Screen
Set DC Input Trigger Screen
Change Setting
Change Setting
Increase Setting
Decrease Setting
N/A
N/A
Load Disconnect Screen
R-Bus Diagnostics Screen