7.7.3 Initialization control commands

Command
#
ADR is followed by address which can be 0 to 30 and is used to access the
1
ADR n
power supply .
Clear status. Sets FEVE and SEVE registers to zero (refer to section 7-8).
CLS
2
Reset command. Brings the power supply to a safe and known state:
RST
3
Output voltage: zero,
Output current: zero,
Output: Off,
FOLD: Off,
The conditional registers (FLT and STAT) are updated, the other registers are
not changed.
Sets the power supply to local or remote mode:
4
RMT
1. RMT 0 or RMT LOC, sets the power supply into Local mode.
2. RMT 1 or RMT REM, sets the unit into remote mode.
3. RMT 2 or RMT LLO, sets the unit into Local Lockout mode (latched remote mode).
5
RMT?
Returns the Remote mode setting:
1. "LOC"- The unit is in Local mode.
2. "REM"- The unit is in Remote mode.
3. "LLO"- The unit is in Local Lockout (latched remote) mode.
6
Returns MD MODE OPTION Status. 1 indicates installed and 0 indicates not
MDAV?
installed.
\
Repeat last command. If \<CR> is received, the power supply will repeat the
7
last command.

7.7.4 ID control commands

#
Command
1
Returns the power supply model identification as an
IDN?
2
Returns the software version as an ASCII string.
REV?
3
Returns the unit serial number. Up to 12 characters.
SN?
4
Returns date of last test. Date format: yyyy/mm/dd
DATE?

7.7.5 Output control commands

#
Command
1
PV n
Sets the output voltage value in Volts. The range of voltage value is described in
Table7-3. The maximum number of characters is 12. See the following examples
for PV n format: PV 12, PV 012, PV 12.0, PV 012.00, etc...
Reads the output voltage setting. Returns the string "n" where "n" is the exact
2 PV?
string sent in the PV n command. When in Local mode, returns the PREVIEW
(front panel) settings in a 5 digits string.
Reads the actual output voltage. Return 5 digits string.
3
MV?
Example: 60V supply sends 01.150, 15.012, 50.000, etc...
Sets the output current value in Amperes. The range of current values is
PC n
4
(See Note 1)
described in Table 7-4. The maximum number of characters is 12. See the
following examples for PC n format: PC 10, PC 10.0, PC 010.00, etc...
5 PC?
Reads the output current setting. Returns the string "n" where "n" is the exact
string sent in the PC n command. When in Local mode, returns the
PREVIEW (front panel) settings in a 5 digits string.
Description
Remote: non-latched remote,
Auto-start: Off,
OVP: maximum,
UVL: zero
Description
Description
54
54
string
ASCII
: LAMBDA, GENX-Y