Checking Power Connections To The Unit - Innovative Technology NV200S Spectral User Manual

Table of Contents

Advertisement

User Manual – NV200 Spectral
<< Back to Contents
Flashes
Indicated Status / Error
Yellow
Cyan
1
1
BNF Lid Open
2
Pay In Path Jam
3
Pay Out Path Jam
2
1
Note Transit Error
2
Note Out Error
3
Motor Stall
3
1
PSU Voltage
2
Note In Calibration Fail
3
Note Out Calibration Fail
4
Note In Speed Fail
5
Note Out Speed Fail
4
2
EEProm Initialisation Fail
3
Download Fail

8.3 Checking power connections to the unit

Check to ensure the power cables are correctly connected to the unit as shown in
the sections below.
Copyright © Innovative Technology Ltd 2019
Recommended Action
Close the BNF Lid
Check the upper note path (where notes are
inserted) and clear and jam/debris
Check the upper note path (where notes are
returned) and clear and jam/debris
Open BNF lid, check that path is clear then
close lid.
Open feeder and NV200 Spectral lid, clear out
note from inside feeder, check reject tray for
note half rejected, close lid to clear error
Open feeder lid, clear out notes from under
tongue, close lid to reset
Power supply is above or below the operational
range. Use power supply that meets the
requirements in
Section 3.4
Remove all notes from tray, clean lightpipe in
tray, power cycle to reattempt startup, if issue
persists return to nearest service centre
Remove all notes from tray, power cycle to
reattempt startup, if issue persists return to
nearest service centre
Remove all notes and power cycle to reattempt
calibration, if persists return
Remove all notes and power cycle to reattempt
calibration, if issue persists return to nearest
service centre
Return to nearest service centre
NV200 Spectral could not update BNF, power
cycle to reattempt download
Doc: User Manual NV200 Spectral
Version: 2.1
Page 65 of 95