Target Volt - (Target Voltage)
This function is available when working
with Lithium and Lead Acid (Pb) chemistry
batteries. Here you can set the target voltage
for each individual cell.
WARNING: Setting the target voltage too
high can damage your battery and cause
your battery to explode. See the packs
manufacturer's recommended settings before
changing this value from the defaults.
Cut Volt - (Cutt-off Voltage)
This function can be activated under
Discharge mode no matter the type
of batteries being discharged. This
function protects a battery from deep
discharging. Refer to the chart on page 6 for
recommended cut-off voltage.
Operating the Charger (continued)
The following functions are available when working with NiMH or
NiCd batteries:
Cycle Mode
In Cycle Mode, users can choose
between charging>discharging or
discharging>charging. There are two
requirements for making the Cycle Mode
accessible: 1. The battery type must be NiMH
or NiCd and 2. The mode must be Cycle. This
mode is intended to help refresh your battery
if it has been sitting for a long period of time.
PROGRAM SELECT(01)
C. Current
D. Current
Target Volt:
4.20V
Cut Volt:
PROGRAM SELECT(01)
C. Current
D. Current
Target Volt:
Cut Volt:
PROGRAM SELECT(01)
Battery Cells:
Mode:
C.Current
D. Current
3.3A
OFF
OFF
3.3A
OFF
4.20V
OFF
5S
Cycle
3.0A
-1.0A