6-2

WIRING DISTANCE

Distance between sensor and power supply
(AWG description)
voltage
wire size
AWG20 (Dia.0.8mm)
AWG18 (Dia.1.0mm)
AWG17 (Dia.1.1mm)
AWG16 (Dia.1.25mm)
AWG15 (Dia.1.4mm)
AWG14 (Dia.1.6mm)
* In case two or more sensors connected, divide the distance by the number.
6-3

WIRING DISTRIBUTION DIAGRAM (WIRING DIAGRAM)

Note : Connect all transmitters and receivers of the same group by synchronized wiring.
Select one transmitter as a master, all the others are as slave.
One master can connect maximum 7 slaves (Transmitter 3, Receiver 4) in one synchronized wire group.
Single level protection, AT output, Environmental output, Tamper output
Transmitter
1CH
A
master
Power supply
Tamper
(N.C.)
(12 to 30VDC)
2 pairs in a straight line, AT output, Environmental output, Tamper output
Transmitter
1CH
A
Master
Tamper
Power supply
(N.C.)
(12 to 30VDC)
12V DC
24V DC
1,000' ( 300m)
7,100' (2,160m)
11,000' (3,400m)
1,550' ( 473m)
13,500' (4,000m)
1,900' ( 580m)
17,000' (5,200m)
2,500' ( 750m)
21,500' (6,550m)
3,100' ( 950m)
4,000' (1,200m)
28,500' (8,690m)
Receiver
Env.
Alarm
(N.C)
(N.C)
Control panel
Receiver
Env.
Alarm
(N.C.)
(N.C.)
Control panel
Synchronized wiring distance
(AWG description)
[ft]
AWG20 (Dia.0.8mm)
AWG18 (Dia.1.0mm) or more
* Maximum 3,300ft(1,000m) and not more.
Transmitter
Receiver
1CH
B
Slave
13
Wire size
Distance
2,850 ' ( 869m)
3,300 ' (1,000m)
[ft]

Advertisement