3.3.4

Pairing

In the Initial Mode, Routers and End Devices must be associated with the corre-
sponding Coordinator. The function is for Router and End Devices only.
1. Press the Function Button 5 times to enter the change Pair ID mode.
2. Status LED blinks
3. Level Index LED turns on to indicate Pair ID.
4. Press the Function Button once to change Pair ID.
5. Press and hold the Function Button for over 3 seconds to save and confirm the
Pair ID.
6. Press the Function Button 3 times to associate with specific Pair ID Coordinator.
7. Error LED turns off when it join a PAN.
3.3.5

Reboot

Press the Function Button for over 3 seconds to reboot the device.