B - Adjustment Mode Instructions

a. Press the MODE button repetitively until the GEAR
b. Referring to the table below, select the desired parameter using the OPEN
observing the number of flashes on the GEAR
light's brightness.
c. Press STOP / SET button to start editing the parameter's value. The TRANSMIT
active.
d. Use the OPEN
and CLOSE
accordingly.
e. Press STOP / SET button to save the parameter's new value or press MODE to leave the value unchanged.
f. Continue from a. above to select another parameter or press MODE to exit adjustment mode.
Parameter
Name
Flashes
MARGIN
1
PE AUTO-CLOSE
2
AUTO-CLOSE
3
LIGHT TIMER
4
* only available with firmware 55 onward

C - Adjusting Force Margins

The Safety Obstruction Force is calculated automatically during
setup. Adjusting this is normally only necessitated by environmental
conditions such as windy or dusty areas, and areas with extreme
temperature changes.
To Increase / Decrease Force Pressure
a. Press the MODE button repetitively until the GEAR
flashing.
b. The LED will start flashing with one flash every second.
c. Press the STOP / STEP button and the MODE button LED and the
TRANSMIT
LED will be lit and the GEAR
every second.
d. By pressing the OPEN button
and CLOSE button
or brighten as the pressure is decreased or increased.
e. Press STOP / SET button to save the new value. (Refer to
Appendix B for margin settings)
f. Test the force again as per Testing Close Cycle and Testing Open
Cycle.
buttons to step through the available options. The light's brightness will change
Value options = Indicated by brightness of main light
1
2
1.0A
1.2A
1.4A
OFF
15sec
30sec
OFF
15sec
30sec
30sec
60sec
90sec
LED will flash once
will increase the force pressure
will decrease the force - Main light will dim
LED starts flashing.
LED. The selected parameter's value is indicated by the main
(DEFAULT parameter underlined)
3
4
5
1.6A
2.0A
-
60sec
90sec
-
60sec
90sec
120sec
120sec
180sec
240sec
LED is
and CLOSE
LED will turn on when editing is
6
7
8
-
-
-
-
-
-
-
-
-
-
-
-
21
buttons and
9
10
-
-
-
-

Hide quick links: