Download Print this page

Table Of Contents - Kasco xStream 2400SF050 Owner's Manual

Advertisement

It is extremely important that proper and suficient voltage
(120V) is supplied to the Fountain motor. Each 120V
Fountain is supplied with a UL and CSA approved C-25
GFI Protected Control Box. The Fountain is to be plugged
into the C-25 outlet labeled "UNIT" and the C-25 plugged
into a properly grounded receptacle (See C-25 Instructions).
It is extremely important to test the GFI breaker in the
control panel upon each installation and reinstallation and
every month thereafter to ensure proper operation.
Kasco Fountains are lightweight, energy eficient, and easy
to install and operate. We strive to produce products that
exceed customer expectations. We hope you enjoy your
Kasco Fountain.
Cord Gauge Chart
Length Gauge
50'
100'
150'
200'
Unit Specs
Model
Voltage
Amps
2400SF
110-120 6.6 - 7.3
Parts Included
1. 2400SF Aerating Fountain (Unit with cord or unit with
Disconnect) (1)
2. Float (with three 50' mooring ropes attached) (1)
3. 1/4" x 3 1/4" screw (3)
4. Debris Screen Sections (3)
9. 1/4" x 1 3/8" screw (3)
11. 1/4" lat washer (9)
13. Flow staightener (1)
16. Nozzle (1)
17. small plugs for nozzle (20) (not pictured)
18. Large plug for nozzle center hole (2) (not pictured)
19. #6 x 1/2" screw (4)
16
14
12
12
Lock
Control
Fountain
rotor
box con-
connec-
amps
nection
tion
18
C-25
Plug into
plug in
C-25
20. #6 lat washer (4)
16
20
19
15
14
13
3
10
11
9
10
11
2
1
4
12
8
7
Also Included:
Cord in separate box (1) (150' or 200' cords only)
Control Box (C-25) (1) (Not Pictured)
TOOLS & SUPPLIES NEEDED
Anchors or stakes for installing unit (2)
# 2 Phillips head screw driver
120V Electrical Supply near pond on a post with
room for mounting the C-25
Three 12" pieces of 1" galvanized pipe or
weighted tubing for weighting ropes (optional)
#10 x 1" long or longer screw(s) for mounting the
C-25 (3)
7/16" Socket and Ratchet (for 1/4" fasteners)
7/16" Wrench (for 1/4" fasteners)
11/32" wrench (for #8 fasteners)
6
5
3

Advertisement